User Tools

Site Tools


internal:proddocs:5906

This is an old revision of the document!


5906 6 Channel Load Controller

INSERT IMAGE OF UNIT

Features

  • Inputs for DC Battery Supply (28V Max)
  • Heartbeat LED Confirming NMEA Transmission
  • NMEA2000® Micro-C Interface Plug
  • Robust Environmentally protected enclosure and connections
  • The unit reports Switch Status (Voltage and Channel Current)
  • Settable channel fuse current and fuse tripping time.



The Oceanic Sytems 5906 6 Channel Load Controller protects each channel with an accurate settable tripping current and tripping time, reporting the channel status over the NMEA2000® network

Electrical and Mechanical

ParameterValueComment
Operating Voltage9 to 32 Volts
Power Consumption300mA @ 24VAverage Operating
CAN Operating Voltage9 to 32 Volts
Load Equivalence Number1LEN
Display Size7“Diagonal
Display Resolution1920 x 1200pixels
Display Brightness1000 nitsOptically Bonded
Contrast Ratio900:1
Viewing Angle85/85/85/85Degrees
Overall Dimensions129x186x44mm

Certifications

ParameterValue
IEC 60945Electromagnetic Compliance
FCCPart 15B Class A
CECE Marked
NMEA2000Version 2.101

Environmental

ParameterValue
Operating Temperature-25°C to 55°C
Storage Temperature-30°C to 60°C
Degree of ProtectionIP66
internal/proddocs/5906.1667485067.txt.gz · Last modified: 2023/07/12 14:11 (external edit)