5720 Fluid Flow Adaptor
Introduction
The Oceanic Systems 5720 Flow Adaptor Module is designed to report fuel flow and usage over the NMEA2000® network using positive displacement flow meters.
These high accuracy sensors connect directly to the 5720 using IP68 rated standard Deutsch connectors (mating connector kit available separately as P/N 5099). The 5720 is compatible with sensors having a single pulsed output as well as those with a 2-phase quadrature output (for cases where reverse flow must be considered). Additionally high accuracy PT100 temperature compensated sensors are fully supported.
As required, the 5720 may be set up to measure two individual flow rates, consumption data based on flow and return rates or total fluid transferred. This configuration along with sensor parameters and network instances may be made to the flow adapter over the NMEA network.
Firmware Revision
The information in this manual corresponds to firmware revision 1.0.0
Features
The NMEA2000® Flow Adaptor Module has the following features:
- Up to 2 flow-meter inputs
- Fuel temperature compensation for greater accuracy
- Accepts quadrature signals to detect reverse flow
- User configurable K-Factor for greater sensor compatibility
- Bunkering mode measures total fuel flow
- Live mode calculates ongoing fuel usage from flow and return sensors
- Robust environmentally protected enclosure and connections
- Tri-colour LED shows status and network activity
Installation
In the box
You will find the following items in the 5270 shipping box:
1 x 5720 NMEA2000® Fluid Flow Adaptor Module
1 x 5720 User Manual (This document)
Mounting the Unit
The unit should be mounted to a flat surface using 4 M4 mounting screws. The unit dimensions and mounting hole locations are shown on the following drawing.
Connecting the NMEA2000® Cable
The unit is connected to the NMEA2000® network by the 5 way micro C socket on the front. Carefully attach the plug of the network drop cable to this socket and tighten by hand until it is fully seated. Take care to match the orientation of the pip inside the socket to the recess inside the drop cable plug. The other end of the drop cable should be connected to a suitable Tee connector on the NMEA2000® network backbone cable.
Connecting the Sensor Cables to the Deutsch Header
The cables from the flowmeter sensors are wired to the 5720 using 6 x 2 way Deutsch DT connectors. Connection to a mating DT socket housing should be made as in the following table:
Terminal | Description |
---|---|
1 | Outward Flowmeter PT100 Sensor (+ve sensing voltage) |
2 | Outward Flowmeter PT100 Sensor (GND potential) |
3 | Outward Flowmeter +ve Power Supply |
4 | Outward Flowmeter GND connection |
5 | Outward Flowmeter Phase B Signal (for reverse flow capable meters) |
6 | Outward Flowmeter Phase A Signal (Hall effect sensor output) |
7 | Return Flowmeter Phase A Signal (Hall effect sensor output) |
8 | Return Flowmeter Phase B Signal (for reverse flow capable meters) |
9 | Return Flowmeter GND connection |
10 | Return Flowmeter +ve Power Supply |
11 | Return Flowmeter PT100 Sensor (GND potential) |
12 | Return Flowmeter PT100 Sensor (+ve sensing voltage) |
https://confluence.osukl.com/download/attachments/1769673/image2020-7-22_11-43-55.png?nolink&308
Typical Connections for Outward flow with thermal compensation:
Terminal | Description |
---|---|
3 | Hall effect VCC |
4 | Hall effect GND |
6 | Hall Effect Output |
1 | PT100 Sensor |
2 | PT100 GND |
Configuration
Before using the 5720 for the first time it needs to be configured with a suitable Oceanic Systems Display Unit.
The following items can be configured on the 5720:
Device Instance
It is possible to install 127 5720 Fluid Flow monitors on a NMEA2000® network. This value must be set to give each sensor a unique address.
Outward Flow Engine Instance
The flow rate from the flowmeter connected to terminals 1 to 6 of the Deutsch Connector are reported on PGN 127489 (Engine Parameters, Dynamic) with this instance.
Return Flow Engine Instance
The flow rate from the flowmeter connected to terminals 7 to 12 of the Deutsch Connector are reported on PGN 127489 (Engine Parameters, Dynamic) with this instance.
Outward Flow Temperature Instance
The temperature from the PT100 sensor connected to terminals 1 and 2 of the Deutsch Connector are reported on PGN 130316 (Temperature, Extended Range) with this instance.
Return Flow Temperature Instance
The temperature from the PT100 sensor connected to terminals 11 and 12 of the Deutsch Connector are reported on PGN 130316 (Temperature, Extended Range) with this instance.
Outward Flow K-Factor
This value must be set to correspond with the parameters of the flowmeter connected to terminals 1 to 6 of the Deutsch Connector. Units are pulses per litre.
Return Flow K-Factor
This value must be set to correspond with the parameters of the flowmeter connected to terminals 7 to 12 of the Deutsch Connector. Units are pulses per litre.
Operation
The 5720 Fluid Flow Adaptor is powered from the NMEA2000® network and transmits data from the flow sensors using the PGNs detailed in the Technical Specifications section.
The LED on the front of the unit flashes blue every second to indicate normal operation or red to indicate an error condition. If the unit is connected to a broken network or one with no other devices, the LED will flash blue in a fast flickering pattern until the network is restored.
Maintenance
- Clean the unit with a soft cloth
- Do not use chemical cleaners as they may remove paint or markings or may corrode the enclosure or seals
- Ensure that the unit is mounted securely and cannot be moved relative to the mounting surface. If the unit is loose, tighten the mounting screws
- Check the security of the cables connected to the NMEA 2000 connector, tighten if necessary
- Check the security of the cables connected to the Deutsch connector
Technical Specification
As Oceanic Systems are constantly improving their products specifications are subject to change without notice. Oceanic System’s products are designed to be accurate and reliable however they should only be used as aids to navigation and not as a replacement for traditional navigation aids and techniques.
Parameter | Comment |
---|---|
NMEA2000 Version | 2.101 Level B |
Maritime Navigation and Radio Communication Equipment | IEC60945 |
CE and FCC | Electromagnetic Compatibility |
NMEA2000® Parameter Group Numbers (PGNs)
Type | PGN No. | PGN Name |
---|---|---|
Monitor | PGN127489 | Engine Parameters, Dynamic |
PGN127497 | Trip Fuel Consumption, Engine | |
PGN130316 | Temperature, Extended Range | |
Protocol | PGN126464 | Tx/Rx PGN List |
PGN126996 | Product Information | |
PGN059392 | ISO Acknowledge | |
PGN059904 | ISO Request | |
PGN060928 | ISO Address Claim | |
PGN126208 | Command/Request Group |
Electrical and Mechanical
Parameter | Value | Comment |
---|---|---|
CAN Operating Voltage | 9 to 32 Volts | |
Power Consumption | 30mA | Average Operating |
Load Equivalence Number | 1 | LEN |
Size | 123 x 104 x 47 | mm |
Weight | 350 | grm |
Environmental
Parameter | Value |
---|---|
IEC 60954 Classification | Protected |
Degree of Protection | IP67 |
Operating Temperature | -25°C to 50°C |
Storage Temperature | -40°C to 70°C |
Relative Humidity | 93%RH @40° per IEC60945-8.2 |
Vibration | 2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 |
Electromagnetic Emission | Conducted and Radiated Emission per IEC 60945-9 |
Electromagnetic Immunity | Conducted, Radiated, Supply, and ESD per IEC 60945-10 |
Safety Precautions | Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12 |