3130 Build Instructions

The 3130 PCB assembly contains components that are sensitive to electrostatic discharge (ESD) – please make sure you are wearing your wrist strap when handling.

Tools: required

  • ST-LINK V2
  • Tag Connect ST-LINK adaptor
  • Small flat head screwdriver
  • Powered NMEA cable
  • Multimeter
  • Crocodile clips
  • An additional Power supply

Programming Instructions

  • Connect the ST-LINK to the USB port of your computer
  • Open STM32CubeProgrammer
  • Connect the 3130 PCB to the NMEA cable. Ensure power is ON.
  • Connect the Tag Connect Cable to the 3130 PCB and the ST-LINK programmer.
  • Select the green 'Connect' Button

  • Select the programming tab

  • Select Browse, and open the bootloader BIN file from S:\Code\Production\3130 Fuel Sender to Resistive Output Adapter\Bootloader - Program this first

*INSERT IMAGE*

Ensure verify programming and run programming boxes are ticked before proceeding</note>

  • Press 'Start Programming'
  • Log should read as follows; If it does not, then program the device again.

  • You can now press disconnect in the top right and remove the TAG CONNECT cable from the board.
  • Open Monex. MINIMUM MONEX VERSION is 3.11. If you are on a lower version you must update this from S:/Code/Published PC Programs/Monex3
  • Press 'Get Prod Info' it should read Model ID: OCEANIC BOOTLOADER 3130-L4
  • Go to the programming tab and press the reprogram button labelled 3310

  • Press reprogram on the dialog that has just popped up
  • Navigate to S:\Code\Production\3130 Fuel Sender to Resistive Output Adapter\Main Program - Program this with Monex - Program this with Monex and select the 3130-2.1.0.bin software and then press Open
  • Device will program, CRC will say 'PASS' and then it will read 'Re-booting to application code' You can now close the dialog
  • Proceed to testing.
If the blue light fails to light switch PSV off and back on again. If it still does not light, check the polarity of the LED. The cathode (K) is marked by a small dot on the silkscreen.

Test Procedure

  • Connect the 3130 to a powered NMEA cable.
  • Open Monex on your computer, MINIMUM MONEX VERSION is 3.10. If you are on a lower version you must update this from S:/Code/Published PC Programs/Monex3.
  • Press 'Get Prod Info' it should read Model ID: Resistive Sender Adaptor

Voltage Safety Testing

  • Set the Rotary switch to '0'.
  • Connect a power supply to the pins on the PCB AS SHOWN BELOW, PAY ATTENTION TO THE POLARITY OF THE CONNECTION!

  • Set the voltage to 3V, turn the supply on.

  • IF THE BLUE LED DOESNT LIGHT IMMEDIATELY THEN TURN THE SUPPLY OFF AND STOP TESTING
  • The Blue LED should turn on and stay on, wait for approximately 10 seconds.

  • turn the supply off and wait for the Blue LED to turn off and return to normal operation (this can take up to 30 seconds).
  • Set the voltage to 30 - 32V, turn the supply on.

  • IF THE BLUE LED DOESNT LIGHT IMMEDIATELY THEN TURN THE SUPPLY OFF AND STOP TESTING
  • The Blue LED should turn on and stay on, wait approxmiately 10 seconds.

  • Turn the supply off and wait for the Blue LED to turn on and return to normal operation (this can take up to 30 seconds)
  • Connect a power supply to the pins on the PCB AS SHOWN BELOW, PAY ATTENTION TO THE POLARITY OF THE CONNECTION!

  • Set the voltage to 1.0V, turn the supply on.

  • IF THE BLUE LED DOESNT LIGHT IMMEDIATELY THEN TURN THE SUPPLY OFF AND STOP TESTING
  • The Blue LED should turn on and stay on, wait for approximately 10 seconds.

  • turn the supply off and wait for the Blue LED to turn off and return to normal operation (this can take up to 30 seconds).
  • Set the voltage to 30 - 32V, turn the supply on.

  • IF THE BLUE LED DOESNT LIGHT IMMEDIATELY THEN TURN THE SUPPLY OFF AND STOP TESTING
  • The Blue LED should turn on and stay on, wait approxmiately 10 seconds.

Resistive Output Testing

* Connect a multimeter in resistance measuring mode across the 2 pins on the PCB

  • Go to the 'Volumetric Mode'

  • Under 'Level Transmit Controls' set the left most instance to '0' and the fluid type to 'FUEL', then click 'TxEnable'.

  • Set the rotary switch to 'A' and put a magnet on the reed switch, the Blue LED should light for 2.5 seconds.
  • Now return the rotary switch to '0', the Blue LED should be double flashing every 2.5 seconds.

  • Change the level to transmit 100%, The measured resistance will state 30 Ohms
  • Change the level transmit to 0%, The measured resistance will state 240 Ohms
  • Change the level transmit 50%, The measured resistance will state 135 Ohms

  • Now, set the rotary switch to 'F', the LED should be off and the measured resistance will be 30 Ohms
  • Set the rotary switch to 'E', the LED should remain off and the measured resistance will be 240 Ohms.
  • Set the rotary switch to 'E' and put a magnet on the reed switch, the Blue LED should light for 2.5 seconds.
  • Now return the rotary switch to '0', the Blue LED should be single flashing every 2.5 seconds.

  • Change the level to transmit 100%, The measured resistance will state 180 Ohms
  • Change the level transmit to 0%, The measured resistance will state 0 Ohms
  • Change the level transmit 50%, The measured resistance will state 90 Ohms

  • Now, set the rotary switch to 'F', the LED should be off and the measured resistance will be 180 Ohms
  • Set the rotary switch to 'E', the LED should remain off and the measured resistance will be 0 Ohms.
  • Set the Rotary switch back to '0'.

TESTING COMPLETED, IF IN ANY DOUBT ASK DEV