User Tools

Site Tools


internal:proddocs:3271-sam2

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
internal:proddocs:3271-sam2 [2022/09/13 11:29] chrissyinternal:proddocs:3271-sam2 [2023/07/12 14:33] (current) – external edit 127.0.0.1
Line 3: Line 3:
 <note warning>**The 3271-SAM2 PCB assembly contains components that are sensitive to electrostatic discharge (ESD) – please make sure you are wearing your wrist strap when handling.**</note> <note warning>**The 3271-SAM2 PCB assembly contains components that are sensitive to electrostatic discharge (ESD) – please make sure you are wearing your wrist strap when handling.**</note>
  
-**Load software Connect to Atmel Flip system version 2.4.6. Select Menu then the file marked 3271_SAM2_v200.hex, Check it has the latest version software on S\Code\Software version matrix. +====== 3271-SAM-2 Programming Instructions ======
-Click on USB plug Icon at top of menu from this select CAN / PEAK, from this Menu Click Initiate then node connect. Un-tick box marked BLJB. Click Run this will load the software to the PCB. +
-  +
-**+
  
 +Connect unit to programming device.
  
-{{:internal:proddocs:sam2.1.png?600|}}{{:internal:proddocs:sam2.2.png?600|}}+{{:internal:proddocs:sam2_conn_prog.jpg?600|}} 
 + 
 +  * Select STM32CubeProgrammer 
 +  * Connect to Unit 
 + 
 +{{:internal:proddocs:connect.jpg?600|}} 
 + 
 +  * Select Device programming   
 + 
 +{{:internal:proddocs:inkedprogramming_tab.jpg?600|}} 
 + 
 +  * Browse and select the S:/Code/Production/3271-SAM2/3271-SAM2-Bootloader 
 + 
 +{{:internal:proddocs:sam2bootloaderdirectory.png?600|}} 
 +   
 +    * Click Start Programming Making sure all the checked boxes are correct 
 + 
 +{{:internal:proddocs:sam2progbootloaderfinished.png?600|}} 
 + 
 +You can now disconnect the unit, if programming unsucessful, erase the device memory and try again. 
 + 
 +  * Open Monex and click 'Get Serial' and 'GetProdInfo', you should see the following 
 + 
 +{{:internal:proddocs:sam2monexprodinfo.png?600|}} 
 + 
 +  * Go to the Programming tab and match the device instance to the Target Select 
 + 
 +{{:internal:proddocs:targetprog.png?600|}} 
 + 
 +  * Click on 3271-SAM2 and the Reprogram on the pop-up 
 +  * Select S:/Code/Production/3271-SAM2/3271-SAM2 
 + 
 +{{:internal:proddocs:sam2programsoftware.png?600|}} 
 + 
 +  * The Device should start programming and should 'PASS', and Reboot to Application Code 
 + 
 +  * Go Back to Device Info Tab and check that Model ID now shows as Sender Averaging Module 
 + 
 +{{:internal:proddocs:sam2prodinfoafterprog.png?600|}} 
 + 
 + 
 +====== 3271-SAM-2 Testing ======
  
 **Conect PCB into Monex. **Conect PCB into Monex.
Line 36: Line 75:
 {{:internal:proddocs:sam2.5.png?600|}} {{:internal:proddocs:sam2.5.png?600|}}
  
-**Assembly.+  Test If device instance changes when hex switch rotated for all values 0-F.
  
-Remove M12 nut (retain for later).+====== Assembly ======
  
-Remove rubber grommet – this can be disposed of as it is not required. 
-** 
  
-{{:internal:proddocs:sam2.6.png?600|}} 
  
-**Fit standoffs so that the PCB sits at the correct height in the plastic case** 
  
-{{:internal:proddocs:sam2.7.png?600|}} 
  
-**Potting: fill the box just under half way, this allows the potting to seep over the edge of the PCB as it’s pushed into the potting.** 
  
-{{:internal:proddocs:sam2.8.png?600|}} 
  
-**Then fill the potting to the shoulder of the switch. Take care not to cover the LED’s during this phase.** 
  
-{{:internal:proddocs:sam2.9.png?600|}} 
  
-**Allocate serial number and print label** 
  
-{{:internal:proddocs:sam2.10.png?600|}} 
  
-**use a bubble bag to protect the unit. Pack into RPT 108 box, with sleeve.** 
  
-{{:internal:proddocs:sam2.11.png?600|}}+ 
 + 
 +===== Fit PCB to box – this will go either way round ===== 
 + 
 +{{:internal:proddocs:sam2casepic.jpg?600|}} 
 + 
 +<note warning>Cover With Epoxy, ensure the LED’s and switches are not covered with epoxy and that the epoxy is smooth and looks professional, if in any doubt ask for a second opinion</note> 
 + 
 +<note important> 
 +The Adaptor is now ready for Labels, Connect to monex for serial numbers</note> 
 + 
 +Fit top label  
 + 
 +{{:internal:proddocs:4291potted.jpg?600|}} 
 + 
 +====== Manual Printing Instructions ====== 
 + 
 +  - Go to (S) Drive. 
 +  - Parts Documents. 
 +  - Select 3271-SAM2 
 +  - Select PDF's. 
 +  - Select 3271-SAM2 user manual and print. 
 + 
 +====== Label  Printing Instructions ==== 
 + 
 +  - Choose labels required  
 +  - Select (LabelDirect) 
 +  - Close (Pop Up) 
 +  - Go to file-open 
 +  - Select - Parts documents 
 +  - Select - 3271-SAM2 
 +  - Select - Labels 
 +  - Select Correct Label 
 +  - Highlight Serial number and change in Text box. 
 +  - Go to Incrementing number Properties and change serial number. 
 +  - Go to file -Print Setup 
 +  - Calibrate the label. 
 + 
 +====== Packaging ====== 
 + 
 +  * Use RPT103 box 
 +  * 2 parts insert 203613 
 +  * Outer sleeve 
 +  * Contents 1 x 3271-SAM2 Sender Averaging Module 
 +  * 1 x User Manual 
 + 
 +{{:internal:proddocs:4291-13.png?600|}} 
internal/proddocs/3271-sam2.1663068583.txt.gz · Last modified: 2023/07/12 14:11 (external edit)