 ====== 3271 Build Instructions ====== ====== 3271 Build Instructions ======
 +
 <note warning>**The 3271 PCB assembly contains components that are sensitive to electrostatic discharge (ESD) – please make sure you are wearing your wrist strap when handling.**</note> <note warning>**The 3271 PCB assembly contains components that are sensitive to electrostatic discharge (ESD) – please make sure you are wearing your wrist strap when handling.**</note>
  
Line 73: Line 74:
  
 <note>For Williams 3271-200 mm add two spacers, one at the top and one at the bottom</note> <note>For Williams 3271-200 mm add two spacers, one at the top and one at the bottom</note>
-**Assemble the Insulator mouldings to the Probe. Check the un-threaded end of the probe for burrs and de-burr if necessary. Slide 200622 Insulators onto the Probe, spacing them approximately 200 mm apart.** +**Assemble the Insulator mouldings to the Probe. Check the un-threaded end of the probe for burrs and de-burr if necessary. Slide 200622 Insulators onto the Probe, spacing them approximately 200 mm apart. 
 +** 
 +<note important>**The outer tube length for Williams is 198mm, the inner rod length is 214mm with CTS 081. 
 +**</note>
 <note important>Select tightly fitting spacers only – this is critical to prevent them sliding when fully assembled.</note> <note important>Select tightly fitting spacers only – this is critical to prevent them sliding when fully assembled.</note>
  
Line 99: Line 102:
  
 ====== Process ====== ====== Process ======
 +
 +<note important>**This is a dry test only to check functionality, The new software is very sensitive and it will fluctuate**</note>
  
 **  -Turn on PSU power and plug in the sender.** **  -Turn on PSU power and plug in the sender.**
-  - **Open monex 3.12**+  - **Open Monex 3.12**
   - **Holding the cable, do an E cal**   - **Holding the cable, do an E cal**
-  - **Put the sender in the fuel (up to the 3/4 point on the sender), do an F cal** +  -** Do an F cal, this will change on the INST** 
-  - **Remove the sender in the fuelgive it a gentle shake and do repeat the E cal** +  
-  **Put the sender halfway between the end and the 3/4 point in the fuel and check 50% on monex**+**Check the Blue light is flashing every 2.5 seconds** 
  
 **Before potting, allow the senders to acclimatise in the potting room for a couple of hours. This will reduce the chance of any condensation on the inner sender body. **Before potting, allow the senders to acclimatise in the potting room for a couple of hours. This will reduce the chance of any condensation on the inner sender body.
Line 163: Line 168:
 ** **
  
-{{:internal:proddocs:3271-12.png|}}+{{:internal:proddocs:3271-12.png|}} 
  
  
Line 171: Line 176:
 ** **
  
-{{:internal:proddocs:3271-13.png|}}+{{:internal:proddocs:3271-13.png|}} {{:internal:proddocs:3271d.jpg?400|}}
  
  
 **To calibrate sender to full, turn rotary switch to the ‘F’ position as indicated in the diagram. **To calibrate sender to full, turn rotary switch to the ‘F’ position as indicated in the diagram.
  
-The sender must be dipped into the tube of fuel to where, the fuel must reach the bottom of the threaded part of the sender body – ensure that the tube has sufficient fuel to reach this level.+The sender must be dipped into the tube of fuel to where, the fuel must reach the bottom of the threaded part of the sender body – ensure that the tube has sufficient fuel to reach this level. Keep clicking the Get Cal button until the Current measured value stops changing. This is a few seconds on a short sender, but could be up to a minute on a 2metre sender. When the value has stopped changing, then calibrate full at the required level. Check that the reading on the big red table goes down very slightly as the sender is raised. DO NOT RESET THE EMPTY, EVEN IF IT READS 2%
  
 Now as for the empty calibration. With a magnet locate the re-calibration place on the top of the unit labelled MAGNET and you will see the blue led remain lit for 2.5 seconds (you can repeat this as many times as you like until you are happy that you have set the FULL position). Now as for the empty calibration. With a magnet locate the re-calibration place on the top of the unit labelled MAGNET and you will see the blue led remain lit for 2.5 seconds (you can repeat this as many times as you like until you are happy that you have set the FULL position).
Line 182: Line 187:
 This is checked with the GET CAL box which should display the FULL values.** This is checked with the GET CAL box which should display the FULL values.**
  
-{{:internal:proddocs:3271-14.png|}}+{{:internal:proddocs:3271-14.png|}} {{:internal:proddocs:3271e.jpg?400|}}
  
  
Line 195: Line 200:
  
 {{:internal:proddocs:3271-15.png|}} {{:internal:proddocs:3271-15.png|}}
 +
 +<note important>**BEFORE PACKING MAKE SURE THERE IS NO FUEL LEFT INSIDE THE SENDER ROD, AS THIS WILL CAUSE THE PACKAGING TO BE FLOODED WITH DIESEL DURING TRANSIT**</note> 
  
  