3501 Build instructions

The 3501 PCB assembly contains components that are sensitive to electrostatic discharge (ESD) – please make sure you are wearing your wrist strap when handling.

Solder wires to PCB and insert cable tie into position see pic below

Programming

Select device programming on Atmel Flip and load hex file required.

Ensure Bit rate is set to 500 Then click (init). Power up device whilst holding SW1 then hit connect you may have to do this twice if error code appears. Ensure BLJB is unticked and then hit run

The device will program ensure all operation flows are green.

Switch off PSU without pressing SW1

Select Monex 3.10 Select Prod info and set serial number.

If working correctly all led's from 3-8 should flash in sequence
  • Go to level transmit controls and change Instance to A B and C

  • Click transmit to standby and change fuel levels to check function

LED 3, 4 and 5 should blink green Click water and fuel LED 3, 4 and 5 should blink red. Change instance to D, E and F

LED 3, 4 and 5 should be solid red and 6, 7 and 8 inactive. Click water and fuel again LED 6, 7 and 8 should blink green.

Apply glue to LED's on board

Insert PCB into casing ensure it sits under the four taps, Tighten cable tie in position and insert yellow button. insert side panels into place (cut to size on cable side)

click the rest of the casing partially into place then insert front panel. Then insert sping into orange slider switch and click everything into place,

Test switch control on monex and check all information. Label unit with required labels and print Data sheet (no manual for this unit)

Packaging

Use a RPT112 box and a 200374 insert