-====== 4291 Build Instructions. ======+====== 4291/4925 Build Instructions. ======
  
  
-<note warning>The 4291  PCB assembly contains components that are sensitive to electrostatic discharge (ESD) – please make sure you are wearing your wrist strap when handling. </note> +<note warning>The 4291 PCB assembly contains components that are sensitive to electrostatic discharge (ESD) – please make sure you are wearing your wrist strap when handling. </note> 
  
  
Line 9: Line 9:
 Connect unit to programming device. Connect unit to programming device.
  
-{{:internal:proddocs:4291-1.png?600|}}+{{:internal:proddocs:prog.jpg?600|}} 
 + 
 +  * Select STM32CubeProgrammer 
 +  * Connect to Unit 
 + 
 +{{:internal:proddocs:connect.jpg?600|}}
  
-  * Select Atmel studio 
   * Select Device programming     * Select Device programming  
-  * Select required Fuses see pictures below. 
  
-{{:internal:proddocs:4291-2.png?400|}}{{:internal:proddocs:4291-3.png?400|}}{{:internal:proddocs:4291-4.png?400|}}+{{:internal:proddocs:inkedprogramming_tab.jpg?600|}}
  
-  * Select Memories +  * Browse and select the S:/Code/Production/4291/4291bootloader
-  * Select Atmel Flip (select ATmeg4C1)+
  
-{{:internal:proddocs:4291-5.png?400|}}{{:internal:proddocs:4291-6.png?400|}}+{{:internal:proddocs:inkedbootloader.jpg?600|}} 
 +   
 +    * Click Start Programming Making sure all the checked boxes are correct
  
-  * Load Hex file (4291-v2.0.6.hex)   +{{:internal:proddocs:success.png?600|}}
-  * Place magnet in position see picture below +
-{{:internal:proddocs:4291-7.png?400|}}{{:internal:proddocs:4291-8.png?400|}}+
  
-  * Select Bit rate (250)                                                              +You can now disconnect the unit, if programming unsucessful, erase the device memory and try again.
-  * Verify Flash+
  
-{{:internal:proddocs:4291-9.png?400|}}{{:internal:proddocs:4291-10.png?400|}}+  * Open Monex and click 'Get Serial' and 'GetProdInfo', you should see the following 
 + 
 +{{:internal:proddocs:monprog.png?600|}} 
 + 
 +  * Go to the Programming tab and match the device instance to the Target Select 
 + 
 +{{:internal:proddocs:targetprog.png?600|}} 
 + 
 +  * Click on 4291 and the Reprogram on the pop-up 
 +  * Select S:/Code/Production/4291/4291 
 + 
 +{{:internal:proddocs:code.png?600|}} 
 + 
 +  * The Device should start programming and should 'PASS', and Reboot to Application Code 
 + 
 +  * Go Back to Device Info Tab and check that Model ID now shows as 4-20mA Tank Level Adapter 
 + 
 +{{:internal:proddocs:success2.png?600|}}
  
 ====== Test Procedure ====== ====== Test Procedure ======
Line 39: Line 57:
  
 • At the start of testing DUT has to be in default configuration state.</note> • At the start of testing DUT has to be in default configuration state.</note>
 +  
 +  ===== Calibrating Sender without Hydrostatic Sensor =====
      
 **TEST EQUIPMENT USED** **TEST EQUIPMENT USED**
  
-  * • NMEA2000 Network with PCAN-View NMEA2000® USB Adaptor+  * 4291 Sender 
 +  * Flat Head Screwdriver 
 +  * 4-20mA Test Unit 
 +  * NMEA Network 
 +  * Magnet
  
 +=== Step 1 ===
 +  * Power up the unit and check connection on Monex
 +  * Connect the Test Box as shown in the picture below
  
-  * • Test unit +{{:internal:proddocs:4291testconnect.jpg?600|}}
-  * • Calibrated Multimeter +
-  * • MONEX installed on a PC+
  
-  {{:internal:proddocs:4291-17.png?400|}}+{{:internal:proddocs:4291testconnect2.jpg?600|}} 
 + 
 +=== Step 2 === 
 + 
 +  * Begin by Empty Calibrating the Sender, do this by setting the Test box to 0 and Left Hex Switch to 'E' and pressing a magnet to the unit in the shown location The blue Led will stay on for 2.5 seconds if carried out correctly. 
 + 
 +{{:internal:proddocs:emptycal4291.jpg?600|}} 
 + 
 +=== Step 3 === 
 + 
 +* Follow by Full Calibrating the Sender, do this by setting the Test Box to 100 and the Left Hex Switch to 'F' and pressing a magnet to the unit in the shown location - The blue Led will stay on for 2.5 seconds if carried out correctly. 
 + 
 +{{:internal:proddocs:fullcal4291.jpg?600|}} 
 + 
 +=== Step 4 === 
 +  * Open Monex and check that the fuel level shown matches the values below 
 + 
 +Test Box 100 = 100% fuel 
 + 
 +Test Box 50 = approximately 65% fuel 
 + 
 +Test Box 0 = 0% fuel
      
 +=== Step 5 ===
      
 +  * Now Cycle Through values 0-7 on the left switch and check if they match the Fluid Type on Monex (Shown below the fluid level Bar Graph)
 +
 +0 = Fuel
 +
 +1 = Fresh
 +
 +2 = Grey
 +
 +3 = Live Well
 +
 +4 = Oil
 +
 +5 = Black
 +
 +6 = Gasoline
 +
 +7 = Rsvd 
 +  
 +  === Step 6 ===
 +  
 +    * Now Cycle Through values 0-F on the right switch and check if the value matches the Device Instance on Monex
 +
 +  ===== Fit PCB to box – this will go either way round =====
 +
 +{{:internal:proddocs:4291case.jpg?600|}}
 +
 +<note warning>Cover With Epoxy, ensure the LED’s and switches are not covered with epoxy and that the epoxy is smooth and looks professional, if in any doubt ask for a second opinion</note>
 +
 +<note important>
 +The Adaptor is now ready for Labels, Connect to monex for serial numbers</note>
  
 +Fit top label 
  
 +{{:internal:proddocs:4291potted.jpg?600|}}
  
 +====== Manual Printing Instructions ======
  
 +  - Go to (S) Drive.
 +  - Parts Documents.
 +  - Select 4291
 +  - Select PDF's.
 +  - Select 4291 user manual and print.
  
 +====== Label  Printing Instructions ====
  
 +  - Choose labels required 
 +  - Select (LabelDirect)
 +  - Close (Pop Up)
 +  - Go to file-open
 +  - Select - Parts documents
 +  - Select - 4291
 +  - Select - Labels
 +  - Select - UL_4291_A-2.0.4
 +  - Highlight Serial number and change in Text box.
 +  - Go to Incrementing number Properties and change serial number.
 +  - Go to file -Print Setup
 +  - Select bradyBBP11-34L(copy 1) and select Calibrate.
 +  - label will calibrate.
  
 +====== Packaging ======
  
 +  * Use RPT103 box
 +  * 2 parts insert 203613
 +  * Outer sleeve
 +  * Contents 1 x 4291 Tank Level Adaptor
 +  * 1 x User Manual
  
-  +{{:internal:proddocs:4291-13.png?600|}}
- +