4291 Build Instructions.
The 4291 PCB assembly contains components that are sensitive to electrostatic discharge (ESD) – please make sure you are wearing your wrist strap when handling.
Programming.
Connect unit to programming device.
- Select Atmel studio
- Select Device programming
- Select required Fuses see pictures below.
- Select Memories
- Select Atmel Flip (select ATmeg4C1)
- Load Hex file (4291-v2.0.6.hex)
- Place magnet in position see picture below
- Select Bit rate (250)
- Verify Flash
Test Procedure
• There should be no devices that are not mentioned in this document on the CAN bus.
• All tests should be carried out at room temperature unless specified otherwise.
• All tests should be performed fully and in specified order.
• At the start of testing DUT has to be in default configuration state.
TEST EQUIPMENT USED
- • NMEA2000 Network with PCAN-View NMEA2000® USB Adaptor
- • Test unit
- • Calibrated Multimeter
- • MONEX installed on a PC
internal/proddocs/4291.1625230989.txt.gz · Last modified: 2023/07/12 14:11 (external edit)