4291 Build Instructions.

The 4291 PCB assembly contains components that are sensitive to electrostatic discharge (ESD) – please make sure you are wearing your wrist strap when handling.

Programming.

Connect unit to programming device.

  • Select Atmel studio
  • Select Device programming
  • Select required Fuses see pictures below.

  • Select Memories
  • Select Atmel Flip (select ATmeg4C1)

  • Load Hex file (4291-v2.0.6.hex)
  • Place magnet in position see picture below

  • Select Bit rate (250)
  • Verify Flash

Test Procedure

• There should be no devices that are not mentioned in this document on the CAN bus.

• All tests should be carried out at room temperature unless specified otherwise.

• All tests should be performed fully and in specified order.

• At the start of testing DUT has to be in default configuration state.

TEST EQUIPMENT USED

  • • NMEA2000 Network with PCAN-View NMEA2000® USB Adaptor
  • • Test unit
  • • Calibrated Multimeter
  • • MONEX installed on a PC

Fit PCB to box – this will go either way round

Secure with 4 x spacers

Take care when fitting the spacer by the NMEA connector, as it may foul when fitting

Fit top plate and screw down

Ensure the LED’s don’t protrude above the height of the plate – if they are like this they need to be removed and fitted lower down

The screws must also be flush after fitting.

Fit top label

The Adaptor is now ready for Labels, Connect to monex for serial numbers

Manual Printing Instructions

  1. Go to (S) Drive.
  2. Parts Documents.
  3. Select 4291
  4. Select PDF's.
  5. Select 4291 user manual and print.

Label Printing Instructions

  1. Choose labels required
  2. Select (LabelDirect)
  3. Close (Pop Up)
  4. Go to file-open
  5. Select - Parts documents
  6. Select - 4291
  7. Select - Labels
  8. Select - UL_4291_A-2.0.4
  9. Highlight Serial number and change in Text box.
  10. Go to Incrementing number Properties and change serial number.
  11. Go to file -Print Setup
  12. Select bradyBBP11-34L(copy 1) and select Calibrate.
  13. label will calibrate.
internal/proddocs/4291.1625231848.txt.gz · Last modified: 2023/07/12 14:11 (external edit)