4291 Build Instructions.

The 4291 PCB assembly contains components that are sensitive to electrostatic discharge (ESD) – please make sure you are wearing your wrist strap when handling.

Programming.

Connect unit to programming device.

  • Select Atmel studio
  • Select Device programming
  • Select required Fuses see pictures below.

  • Select Memories
  • Select Atmel Flip (select ATmeg4C1)

  • Load Hex file (4291-v2.0.6.hex)
  • Place magnet in position see picture below

  • Select Bit rate (250)
  • Verify Flash

Test Procedure

• There should be no devices that are not mentioned in this document on the CAN bus.

• All tests should be carried out at room temperature unless specified otherwise.

• All tests should be performed fully and in specified order.

• At the start of testing DUT has to be in default configuration state.

Calibrating Sender to Sensor

TEST EQUIPMENT USED

  • 4291 Sender
  • Flat Head Screwdriver
  • Hydrostatic Sensor
  • NMEA Network
  • Calibrating Pipe on staircase (production side)

Step 1

Power on the NMEA power supply and set to 12V before turning on.

You will need an NMEA connector in the production staircase, and connect the 4291, the blue LED should be double blinking every few seconds.

Open Monex on your PC, click 'Get Serial' and 'Get ProdInfo', you shoud see the 4291 show up.

Step 2

Connect the Hydrostatic sensor to the 4291 as shown:

Step 3

Make sure the water Pipe is empty before connecting the hydrostatic sensor.

Open the Left valve on the staircase pipe and screw in the hydrostatic sensor, make sure it is level to the ground when taking readings and calibrating.

Use the screwdriver and turn the left Hex switch to 'E', place magnet next to 'magnet' label (under both switches), The blue LED will start to blink rapidly, hold the magnet in place until the LED turns solid blue.

Check Monex to see that the sender is transmitting 0%

Step 4

Now proceed to fill the pipe on the staircase to 1.306m (make sure its as precise as possible).

When the water level is at 1.306m, make sure the hydrostatic sensor is as horizontal as possible.

Turn the left Hex switch to 'F', place magnet next to 'magnet' label (under both switches), The blue LED will start to blink rapidly, hold the magnet in place until the LED turns solid blue.

Check Monex to see that the sender is transmitting 100%.

Step 5

On monex go into the Volumetric mode tab, click 'Read table from sender'.

Now Drain the water slightly, and each time compare the water level to the monex output, in unsure then ask for help.

If the readings are all within 1% of the real value then calibration is finished.

TEST EQUIPMENT USED

  • • NMEA2000 Network with PCAN-View NMEA2000® USB Adaptor
  • • Test unit
  • • Calibrated Multimeter
  • • MONEX installed on a PC

Fit PCB to box – this will go either way round

Secure with 4 x spacers

Take care when fitting the spacer by the NMEA connector, as it may foul when fitting

Fit top plate and screw down

Ensure the LED’s don’t protrude above the height of the plate – if they are like this they need to be removed and fitted lower down

The screws must also be flush after fitting.

Fit top label

The Adaptor is now ready for Labels, Connect to monex for serial numbers

Manual Printing Instructions

  1. Go to (S) Drive.
  2. Parts Documents.
  3. Select 4291
  4. Select PDF's.
  5. Select 4291 user manual and print.

Label Printing Instructions

  1. Choose labels required
  2. Select (LabelDirect)
  3. Close (Pop Up)
  4. Go to file-open
  5. Select - Parts documents
  6. Select - 4291
  7. Select - Labels
  8. Select - UL_4291_A-2.0.4
  9. Highlight Serial number and change in Text box.
  10. Go to Incrementing number Properties and change serial number.
  11. Go to file -Print Setup
  12. Select bradyBBP11-34L(copy 1) and select Calibrate.
  13. label will calibrate.

Packaging

  • Use RPT103 box
  • 2 parts insert 203613
  • Outer sleeve
  • Contents 1 x 4291 Tank Level Adaptor
  • 1 x User Manual

Manual Printing Instructions

  1. Go to (S) Drive.
  2. Parts Documents.
  3. Select 4291
  4. Select PDF's.
  5. Select 4291 user manual and print.

Label Printing Instructions

  1. Choose labels required
  2. Select (LabelDirect)
  3. Close (Pop Up)
  4. Go to file-open
  5. Select - Parts documents
  6. Select - 4291
  7. Select - Labels
  8. Select - UL_4291_A-2.0.4
  9. Highlight Serial number and change in Text box.
  10. Go to Incrementing number Properties and change serial number.
  11. Go to file -Print Setup
  12. Select bradyBBP11-34L(copy 1) and select Calibrate.
  13. label will calibrate.
internal/proddocs/4291.1633680920.txt.gz · Last modified: 2023/07/12 14:11 (external edit)