internal:proddocs:4410
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| internal:proddocs:4410 [2021/06/25 14:38] – [Assembly Instructions] chrissy | internal:proddocs:4410 [2023/12/04 10:21] (current) – kacper | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | ====== | + | ====== 4410 Build Instructions ====== |
| - | <note warning> | + | <note warning> |
| + | <note important> | ||
| **Tools: required** | **Tools: required** | ||
| * 5mm long drive socket + driver | * 5mm long drive socket + driver | ||
| Line 9: | Line 10: | ||
| ====== Programming Instructions ====== | ====== Programming Instructions ====== | ||
| - | <note important> | + | Connect |
| - | | + | {{: |
| - | * | + | |
| - | * | + | |
| - | * | + | |
| - | * | + | |
| - | * Then press ‘Set’ the read registers should all read ‘OK’ | + | |
| - | < | + | * Select STM32CubeProgrammer |
| + | * Connect to Unit | ||
| + | {{: | ||
| - | </ | + | * Select Device programming |
| - | This part of the test needs to be done using the correct software from the screen shots, which is found at S/parts docs/4410/ | + | |
| + | {{: | ||
| + | |||
| + | * Browse and select | ||
| + | |||
| + | {{: | ||
| + | |||
| + | * Click Start Programming Making sure all the checked boxes are correct | ||
| + | |||
| + | {{: | ||
| + | |||
| + | You can now disconnect the unit, if programming unsucessful, | ||
| + | |||
| + | * Open Monex and click 'Get Serial' | ||
| + | |||
| + | {{: | ||
| + | |||
| + | * Go to the Programming tab and match the device instance to the Target Select | ||
| + | |||
| + | {{: | ||
| - | {{: | + | * Click on 4410 and the Reprogram on the pop-up |
| + | * Select S:/ | ||
| - | Using the screen shots select ‘Fuses’ .Then match your inputs to the screen shot inputs. Then select ‘program’. | + | {{: |
| - | The read registers should still read ok. | + | |
| - | {{: | + | * The Device should start programming and should ' |
| - | Select ‘Memories’ select correct software | + | * Go Back to Device Info Tab and check that Model ID now shows as Switch Input Module |
| - | Close program and proceed with build. | + | |
| - | {{: | + | {{: |
| ====== Test Procedure ====== | ====== Test Procedure ====== | ||
| Line 41: | Line 57: | ||
| </ | </ | ||
| - | Connect the CAN to the CAN chassis plug on the logic board as shown in picture, place a +12 or +24 volt power supply into pins 1 and 2 of the terminal block connector. | + | Connect the CAN to the CAN chassis plug on the logic board as shown in picture |
| - | {{: | + | {{: |
| - | {{: | + | {{: |
| + | |||
| + | Test all inputs one by one using the probe and monitoring the output in the test program, the voltage applied to each input should also be +30V. Also make sure that each input LED, alongside the software test program output changing. | ||
| + | |||
| + | {{: | ||
| + | |||
| + | {{: | ||
| + | |||
| + | {{: | ||
| {{: | {{: | ||
| Line 60: | Line 84: | ||
| Screw 4 x 201076 onto the 4 x 201074. | Screw 4 x 201076 onto the 4 x 201074. | ||
| - | Place the board 10258-B in to the housing 201030 Remove rubber grommet and nut from PL1 and replace with shim washer x 5 203017. | + | Place the board 10258-B in to the housing 201030 Remove rubber grommet and nut from PL1 and replace with shim washer x 8 203017. |
| {{: | {{: | ||
| Line 77: | Line 101: | ||
| {{: | {{: | ||
| - | |||
| - | Once the backing plate is secured, place the Oceanic Systems product description and serial number sticker onto the unit side panel square and central as per picture. | ||
| - | |||
| - | {{: | ||
| - | |||
| - | |||
| - | |||
| - | |||
| + | Once the backing plate is secured, place the Oceanic Systems product description and serial number Label onto the unit side panel square and central as per picture. | ||
| + | ====== Manual Printing Instructions ====== | ||
| + | - Go to (S) Drive. | ||
| + | - Parts Documents. | ||
| + | - Select 4410 | ||
| + | - Select PDF's. | ||
| + | - Select 4410 user manual and print. | ||
| + | ====== Label Printing Instructions ==== | ||
| + | - Choose labels required | ||
| + | - Select (LabelDirect) | ||
| + | - Close (Pop Up) | ||
| + | - Go to file-open | ||
| + | - Select - Parts documents | ||
| + | - Select - 4410 | ||
| + | - Select - Labels | ||
| + | - Select - UL_4410 or for (princess) 729167 | ||
| + | - Highlight Serial number and change in Text box. | ||
| + | - Go to Incrementing number Properties and change serial number. | ||
| + | - Go to file -Print Setup | ||
| + | - Select bradyBBP11-34L(copy 1) and select Calibrate. | ||
| + | - label will calibrate. | ||
| + | {{: | ||
| + | ====== Packaging ====== | ||
| + | Use RPT112 box and 200372 insert | ||
| + | 203373 outer sleeve | ||
| + | {{: | ||
| + | --- // | ||
internal/proddocs/4410.1624631921.txt.gz · Last modified: 2023/07/12 14:11 (external edit)