Line 26: Line 26:
 Connect the NMEA 2000 power calbe and turn the power supply to 12V before turning it on. Connect the NMEA 2000 power calbe and turn the power supply to 12V before turning it on.
  
-INSERT IMAGE+{{:internal:proddocs:5720_nmea_power.jpg?600|}}
  
 Connect the STM32 Programmer to CONN2 on the 5720 PCB as shown below Connect the STM32 Programmer to CONN2 on the 5720 PCB as shown below
  
-INSERT IMAGE+{{:internal:proddocs:5720_stm32_programmer_conn2.jpg?600|}}
  
 Open STM32 Programmer, click 'Connect' and go to the Programming tab Open STM32 Programmer, click 'Connect' and go to the Programming tab
Line 47: Line 47:
  
 You can now close the STM32 programmer and open Monex You can now close the STM32 programmer and open Monex
- 
-Click on Get Serial and Get ProdInfo, you should see the same as below: 
- 
-INSERT IMAGE 
  
 Go to the Fuel Flow Tab and click 'Reprogram!', then choose S:/Code/Production/5720/5720 Fuel Flow Go to the Fuel Flow Tab and click 'Reprogram!', then choose S:/Code/Production/5720/5720 Fuel Flow
Line 61: Line 57:
 Connect the unit to the 5720 Testing Rig Connect the unit to the 5720 Testing Rig
  
-INSERT IMAGE+{{:internal:proddocs:5720_test_rig.jpg?600|}}
  
 Open Monex on the 'Fuel Flow' Tab and set the Instances and values to match the image below: Open Monex on the 'Fuel Flow' Tab and set the Instances and values to match the image below:
Line 77: Line 73:
 {{:internal:proddocs:5720_initial_setup_values_2.png?600|}} {{:internal:proddocs:5720_initial_setup_values_2.png?600|}}
  
-Now set the left switch (L) UpThe flow should be approximately 3000Flow total should be incrementing approximately every second. Return Flow should remain 'Unavailable'.+The Tests Below will Require you to change the state of the switches on the test rig: 
 + 
 +{{:internal:proddocs:5720_switches.jpg?600|}} 
 + 
 +**Now set the left switch (L) Up** 
 + 
 +The flow should be approximately 3000 
 + 
 +Flow total should be incrementing approximately every second  
 + 
 +Return Flow should remain 'Unavailable'. 
 + 
 +**Now set the left switch (L) Down**  
 + 
 +The Return flow should be approximately 3000 
 + 
 +Return Total should be incrementing approximately every second 
 + 
 +Flow Should remain 'Unavailable'
 + 
 +**Return the Left switch (L) to the middle position** 
 + 
 +**Now set the Right switch (R) Up** 
 + 
 +The flow and Return should remain 'Unavailable'  
 + 
 +The Flow Total should decrement approximately every 6 seconds.
  
-Now set the left switch (L) Down, The Return flow should be approximately 3000, Return Total should be incrementing approximately every second. Flow Should remain 'Unavailable'.+**Now set the Right Switch (R) Down**
  
-Return the Left switch (L) to the middle position+The Return flow should be approximately 600
  
-Now set the Right switch (R) Up, The flow and Return should remain 'Unavailable' and the Flow Total should decrement approximately every 6 seconds.+Return Total should increment approximately every 6 seconds.
  
-Now set the Right Switch (R) Down, The Return flow should be approximately 600, Return Total should increment approximately every 6 seconds.+**Now return the Right Switch (R) to the middle position**
  
-Now return the Right Switch (R) to the middle position.+**Now Click both 'Reset Flow Total' and 'Reset Return Total'**
  
-Now Click both 'Reset Flow Total' and 'Reset Return Total' - both totals should return to '0'+Both totals should return to '0'
  
  