| Connect the NMEA 2000 power calbe and turn the power supply to 12V before turning it on. | Connect the NMEA 2000 power calbe and turn the power supply to 12V before turning it on. | ||
| - | INSERT IMAGE | + | {{: |
| Connect the STM32 Programmer to CONN2 on the 5720 PCB as shown below | Connect the STM32 Programmer to CONN2 on the 5720 PCB as shown below | ||
| - | INSERT IMAGE | + | {{: |
| Open STM32 Programmer, click ' | Open STM32 Programmer, click ' | ||
| Line 47: | Line 47: | ||
| You can now close the STM32 programmer and open Monex | You can now close the STM32 programmer and open Monex | ||
| - | |||
| - | Click on Get Serial and Get ProdInfo, you should see the same as below: | ||
| - | |||
| - | INSERT IMAGE | ||
| Go to the Fuel Flow Tab and click ' | Go to the Fuel Flow Tab and click ' | ||
| Line 61: | Line 57: | ||
| Connect the unit to the 5720 Testing Rig | Connect the unit to the 5720 Testing Rig | ||
| - | INSERT IMAGE | + | {{: |
| Open Monex on the 'Fuel Flow' Tab and set the Instances and values to match the image below: | Open Monex on the 'Fuel Flow' Tab and set the Instances and values to match the image below: | ||
| Line 76: | Line 72: | ||
| {{: | {{: | ||
| + | |||
| + | The Tests Below will Require you to change the state of the switches on the test rig: | ||
| + | |||
| + | {{: | ||
| **Now set the left switch (L) Up** | **Now set the left switch (L) Up** | ||