internal:proddocs:9025
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| internal:proddocs:9025 [2022/07/20 14:35] – chrissy | internal:proddocs:9025 [2025/11/18 13:22] (current) – updated image for 9025 program file zbigniew | ||
|---|---|---|---|
| Line 46: | Line 46: | ||
| - | {{: | + | {{: |
| <note important> | <note important> | ||
| Double check that you have selected the correct Hex file and it has been loaded successfully** | Double check that you have selected the correct Hex file and it has been loaded successfully** | ||
| </ | </ | ||
| + | |||
| + | {{: | ||
| + | |||
| + | **Once you are satisfied the correct Hex file has been selected and loaded successfully you can then proceed to program the J1939 to NMEA2000 adaptor. | ||
| + | |||
| + | Press the Program button** | ||
| + | |||
| + | **Keep an eye on the console output window for feedback on how the programming procedure is running. | ||
| + | ** | ||
| + | |||
| + | {{: | ||
| + | |||
| + | **At the end of the programming procedure you will be greeted with a Programming/ | ||
| + | ** | ||
| + | |||
| + | {{: | ||
| + | |||
| + | **Test Procedure** | ||
| + | |||
| + | **Select J1939 SIM from the test equipment** | ||
| + | |||
| + | **Using test lead, fit 3 x wires | ||
| + | White / black / blue** | ||
| + | |||
| + | < | ||
| + | Note –you will require 3 cables from the network to do the test, Once this is connected, the green LED will also flash rapidly, see pics below**</ | ||
| + | |||
| + | {{: | ||
| + | |||
| + | |||
| + | < | ||
| + | Optional: For further testing you can: unplug the 3185 simulating device from the J1939 sim kit (keep both connections to the 9025 board). | ||
| + | Open PCan-view, filter settings - Extended, OK. Then go to S: | ||
| + | Now in Pcan-view you should see CAN data popping up. Two lines every 0.1s and two other lines every 1s (If this does not show up, close pcan-view and all other CAN bus programs, and launch again in this sequence. | ||
| + | When you tick the random box in NMEA Simulator, the data for both sets of boxes should start changing. If it does not, make sure the instance switch is set to the correct instance. **</ | ||
| + | |||
| Line 65: | Line 101: | ||
| {{: | {{: | ||
| - | |||
| - | |||
internal/proddocs/9025.1658327738.txt.gz · Last modified: 2023/07/12 14:11 (external edit)