User Tools

Site Tools


internal:proddocs:9101

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
internal:proddocs:9101 [2022/06/27 11:08] kacperinternal:proddocs:9101 [2023/07/12 14:33] (current) – external edit 127.0.0.1
Line 15: Line 15:
 ===== Assembling/Connecting and Testing Seatek Engine Adapter using Test Box ===== ===== Assembling/Connecting and Testing Seatek Engine Adapter using Test Box =====
 **This Section outlines all connections that need to be made before testing can begin and all testing that follows** **This Section outlines all connections that need to be made before testing can begin and all testing that follows**
 +
 +==== Before Starting ====
 +Before you begin testing you must cut a track on the PCB with a scalpel and carry out a continuity check using a multimeter to make sure the track is definitely cut.
 +The track you should cut is shown below:
 +
 +{{:internal:proddocs:cutting_track.jpg?800|}}
  
 ==== Step 1 ==== ==== Step 1 ====
Line 317: Line 323:
 Click the Ignition Button again to turn it off, The Stop button should light Red. Click the Ignition Button again to turn it off, The Stop button should light Red.
  
-**Return all switched to position 1 and return the ignition switch to the starting vertical position**+==== Step 25 ==== 
 + 
 +Now Test the STOP functionality of the Seatek Test Box. 
 + 
 +Do This by turning the ignition switch at 45 deg to the right in the 'on' position. 
 + 
 +INSERT IMAGE OF SEATEK TEST BOX 
 + 
 +Monex Should look like this: 
 + 
 +INSERT IMAGE OF MONEX 
 + 
 +Now Proceed to press and HOLD the STOP button on the Seatek test box and monitor Monex 
 + 
 +**IF THE STOP RELAY ON SEATEK PCB TOGGLES RAPIDLY THEN STOP TESTING** 
 + 
 +Monitor Monex while holding the button, it should look as follows: 
 + 
 +INSERT IMAGE OF MONEX 
 + 
 +If there is no rapid toggling then hold down the stop button on the test box and proceed to turn the ignition switch all the way to the right - On monex the STOP button should not be lit, while the START button should light Yellow. 
 + 
 +IF THIS IS NOT THE CASE THEN STOP TESTING AND ASK DEV 
 + 
 +Now hold down the STOP button again, and click START on monex - START should not light, and STOP should be constantly lit RED. 
 + 
 +**Return all switched to position 1 and return the ignition switch to the starting vertical position*
  
 **Turn Power off** **Turn Power off**
  
 **IF ALL TESTS WERE ACCURATE THEN TESTING IS COMPLETED, IF YOU HAVE ANY DOUBTS THEN ASK DEV** **IF ALL TESTS WERE ACCURATE THEN TESTING IS COMPLETED, IF YOU HAVE ANY DOUBTS THEN ASK DEV**
internal/proddocs/9101.1656328111.txt.gz · Last modified: 2023/07/12 14:11 (external edit)