Line 31: Line 31:
 You should find the following items in the 3165 shipping box: You should find the following items in the 3165 shipping box:
  
-1 x 3165 NMEA2000® Rudder Angle Adaptor+1 x 5906 6 Channel Load Controller
  
 1 x NMEA2000 drop cable 1 x NMEA2000 drop cable
  
-1 x 3165 User Manual (This document)+1 x 5099 Male Deutsch Adapter Kit 
 + 
 +1 x 5906 User Manual (This document)
  
 ==== Mounting the Unit ==== ==== Mounting the Unit ====
  
-The unit is designed to be cable tied either onto a suitable location or into the main cable harness.+The unit is designed to be screwed onto a suitable location.
  
 ==== Connecting the NMEA2000® Cable ==== ==== Connecting the NMEA2000® Cable ====
Line 47: Line 49:
 Ensure that the locking ring is securely tightened so that the connection remains waterproof and sound. Ensure that the locking ring is securely tightened so that the connection remains waterproof and sound.
  
-==== Connecting the Rudder Angle Sensor Cable ====+==== Connecting Battery Supply Cables ====
  
-Resistive rudder angle senders have two terminals, the sensor terminal may be marked with an “S” or “G” and the other marked with a ground or “-“ markIf they are not marked the ground or “-“ may be the terminal which is connected to the metal housing and the sensor terminal will be insulated from the metal housing. +Channel Load Controllers have two power terminals , The positive terminal is marked with a "+" (Red Colour) and the ground terminal is marked with a "-" (Black Colour)Ensure that the gauge of wire used is adequate for the power it will be carrying to the load.
-Ensure that there are NO other cables connected to the rudder angle sender and then connect +
-the 2 metre 2 core gray cable to those terminals according to the following table.+
  
-^Sender Terminal^Wire Colour| +**Warning - Unit must be installed by a qualified electrical engineer. Incorrect Connections or Cables Used may result in damage to the unit or load, PERSONAL INJURY or DEATH** 
-|Sensor (S or G)|Red|+ 
 + 
 +^Power Terminal^Wire Colour| 
 +|Positive (+)|Red|
 |Ground (-)|Black| |Ground (-)|Black|
 +
 +==== Connecting Channel Supplies to Deutsch Connector ====
 +The 6 Channel supply outputs are taken from the Load Controller using a DT15-12PA Deutsch Connector. Each wire should be of adequate gauge to carry the load rated current 
 +
 +**Warning - Unit must be installed by a qualified electrical engineer. Incorrect Connections or Cables Used may result in damage to the unit or load, PERSONAL INJURY or DEATH**
  
 ===== Configuration ===== ===== Configuration =====
product/5906.1668762835.txt.gz · Last modified: 2023/07/12 14:11 (external edit)