This is an old revision of the document!
Table of Contents
5906 6 Channel Load Controller
INSERT IMAGE OF UNIT
Features
- Inputs for DC Battery Supply (28V Max)
- Heartbeat LED Confirming NMEA Transmission
- NMEA2000® Micro-C Interface Plug
- Robust Environmentally protected enclosure and connections
- The unit reports Switch Status (Voltage and Channel Current)
- Settable channel fuse current and fuse tripping time.
The Oceanic Sytems 5906 6 Channel Load Controller protects each channel with an accurate settable tripping current and tripping time, reporting the channel status over the NMEA2000® network
The unit is able to provide power to 6 individual channels, each with a configurable fuse and tripping time.
The unit is suitable for powering loads like Lighting, x ,x. Each channel contains a status LED for displaying if the channel is On/Off/Tripped.
The Power connections utilise copper tube crimps with an M6 Bolt allowing for secure and reliable connection.
The unit utilises a waterproof and corrosion resistant DT15-12PA Deutsch Connector for the 6 output channels, which allows for a secure and reliable connection.
The 5906 has a blue LED that flashes as the unit transmits data over the network with configuration done with a suitable Oceanic Systems Display Unit, Our Puma PC software or pre-configuration when ordering direct from Oceanic Systems.
Up to 254 units can be present on a single network.
Unit Dimensions
INSERT DIMENSIONS
5099 Male Deutsch Adaptor Kit
INSERT IMAGE
Design Standards
| NMEA2000® | Level B |
| Maritime Nav and RadioComm Equipment | IEC60945 |
| CE and FCC | Electromagnetic Compatibility |
NMEA2000® PGNs
| Type | PGN Number | PGN Name | |
|---|---|---|---|
| Monitor | PGN127501 | Binary Status Report | |
| Protocol | PGN059392 | ISO Acknowledgement | |
| PGN059904 | ISO Request | ||
| PGN060928 | ISO Address Claim | ||
| PGN126208 | Command/Request Group | ||
| PGN126464 | Tx/Rx PGN List | ||
| PGN126993 | Transmit Heartbeat | ||
| PGN126996 | Product Information | ||
| PGN126998 | Configuration Information |
Electrical and Mechanical
| Parameter | Value | Comment |
|---|---|---|
| Operating Voltage | 9 to 32 Volts | DC Voltage |
| Power Consumption | 80mA @ 24V | Average Operating |
| Load Equivalence Number | 2 | LEN |
| Reverse Battery Protection | ???? | Indefinitely |
| Load Dump Protection | ???? | SAE J1113 |
| Size | mm | ???? |
| Weight | gr | ???? |
Environmental
| Parameter | Values |
|---|---|
| IEC 60954 Classification | Protected |
| Degree of Protection | IP64 |
| Operating Temperature | ???? |
| Storage Temperature | -40°C to 70°C |
| Relative Humidity | 93%RH @40° per IEC60945-8.2 |
| Vibration | 2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 |
| Electromagnetic Emission | Conducted and Radiated Emission per IEC 60945-9 |
| Electromagnetic Immunity | Conducted, Radiated, Supply, and ESD per IEC 60945-9 |
| Safety Precautions | Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945- 12 |