 **At this point programming and verification on this device (J1939 to NMEA2000 adaptor) is now complete you may now disconnect the CAN power connector and the MPLAB ICD 3 RJ-11 connector. **At this point programming and verification on this device (J1939 to NMEA2000 adaptor) is now complete you may now disconnect the CAN power connector and the MPLAB ICD 3 RJ-11 connector.
 +
  
 {{:internal:proddocs:3185.1.png?600|}} {{:internal:proddocs:3185.1.png?600|}}
  
  
-<note tip>Do not forget to put the jumper on 
-</note> 
  
 +====== Testing Procedure======
  
-Ensure the logic board is programmed with the latest firmware revision before placing into the housing as once installed you will not be able to program the unit or flash the firmware. 
  
-You are now ready to connect the unit to the PC to assign the unit the serial number from the sticker and to test. +Select the test equipment from the shelf
-Connect unit to Monex (blue LED will flash fast, this is normal) then select ‘get prod info’ and check part number and version are correct. Input serial number and select ‘set serial’ then select ‘get prod info’ and check serial number is correct in all required boxes. +
-Check all instances work on the left hand rotary switch – 0 through to 15 this should be reflected on Monex+
  
-You can now close Monex 
  
  
-====== Testing ====== 
- 
- 
- 
-**Select this test equipment from the shelf.** 
  
  
Line 97: Line 88:
  
  
 +Get this test equipment from the shelf
 Using test lead, fit 3x wires Using test lead, fit 3x wires
 White / black / blue White / black / blue
  
 Connect the J1939 simulator Connect the J1939 simulator
 +Note –you will require 3 cables from the network to do the test,
  
 +Once this is connected, the green LED will also flash rapidly.
 +
 +{{:internal:proddocs:3185..11.png?600|}}
 +
 +Image with all 3 cables connected below.
 +
 +{{:internal:proddocs:3185..12.png?600|}}
 +
 +See pic below for program.
 +
 +{{:internal:proddocs:3185..13.png?600|}}
 +
 +Check all instances again
 +
 +Check the up / down buttons, as long as the values change the unit is ok.
 +
 +This completed programming and test.
 +
 +Add 4x 200943 spacers to existing studs in metalwork.
 +
 +Place the board 10262 in to the housing. Remove the rubber grommet and nut from PL1.
 +
 +
 +{{:internal:proddocs:3185..14.png?600|}}
 +
 +Screw 201485 onto studs using the 5mm long socket securing the board to the housing.
 +Taking time to align the two switches with the top cover.
 +
 +
 +{{:internal:proddocs:3185..15.png?600|}}
 +
 +
 +Place the rear cover 201030 on to the unit and screw down using screw 201074 making sure the countersunk holes are facing outwards towards you.
 +
 +{{:internal:proddocs:3185..16.png?600|}}
 +
 +Once the backing plate is secured, place the Oceanic Systems product description and serial number sticker onto the unit side panel square and central as shown.
 +
 +{{:internal:proddocs:3185-16.png?600|}}
 +
 +This can now be packed into its box with sleeve and QC label.
  
-<note>Note –you will require 3 cables from the network to do the test,</note> 
  
-<note tip>Once this is connected, the green LED will also flash rapidly</note> 
  
   
-**+
  