 {{:internal:proddocs:3281...jpg?600|}}{{:internal:proddocs:img_20220505_150521.jpg?600|}} {{:internal:proddocs:3281...jpg?600|}}{{:internal:proddocs:img_20220505_150521.jpg?600|}}
 +
 +**Ensure the check boxes are as shown below and then select “Start Programming”**
  
 {{:internal:proddocs:img_20220506_074850.jpg?600|}} {{:internal:proddocs:img_20220506_074850.jpg?600|}}
  
 +<note important>**Now, the blue LED should be on solid.
 +Open Monex 3.12, Select the Programming tab, and then press “3281”**
 +</note>
 +
 +{{:internal:proddocs:img_20220505_150709.jpg?600|}}
 +
 +**Press the re-program button**
 +
 +{{:internal:proddocs:3271..6.png?600|}}
 +
 +**Navigate to S:\Code\Production\3271 Fuel Level Sender\Program AFTER Rev J and select 3271-v5.bin, then press “open”.
 +**
 +**Browse to the folder S:\Code\Production\3281 water Level Sender\Program AFTER Rev J\
 +
 +Then select 3281bootloader.bin**
 +
 +**The tool will now indicate it is programming, it will then show a CRC and PASS, and finally will reboot to application code.**
 +
 +{{:internal:proddocs:3271..8.png?600|}}
  
 <note important>**Before potting, allow the senders to acclimatise in the potting room for a couple of hours. This will reduce the chance of any condensation on the inner sender body.**</note> <note important>**Before potting, allow the senders to acclimatise in the potting room for a couple of hours. This will reduce the chance of any condensation on the inner sender body.**</note>