internal:proddocs:3420
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| internal:proddocs:3420 [2021/12/06 11:17] – kacper | internal:proddocs:3420 [2023/07/26 10:01] (current) – eral | ||
|---|---|---|---|
| Line 70: | Line 70: | ||
| ===== Testing Instructions ===== | ===== Testing Instructions ===== | ||
| + | |||
| + | <adm warning> | ||
| <note warning> The 3420 Testing process involves HIGH VOLTAGE, Make sure to disconnect power when handling connections, | <note warning> The 3420 Testing process involves HIGH VOLTAGE, Make sure to disconnect power when handling connections, | ||
| Line 83: | Line 85: | ||
| * Variac | * Variac | ||
| * Electric Tape | * Electric Tape | ||
| + | * Multimeter | ||
| === Step 1 === | === Step 1 === | ||
| Line 105: | Line 108: | ||
| {{: | {{: | ||
| + | |||
| + | **Now Connect the black wire from the miltimeter to the same black current transformer output wire** | ||
| === Step 5 === | === Step 5 === | ||
| Line 110: | Line 115: | ||
| {{: | {{: | ||
| + | |||
| + | **Now Connect the Red wire from the miltimeter to the same red current transformer output wire** | ||
| ===Step 6 === | ===Step 6 === | ||
| - | Wrap Electric Tape around the crocodile clips to ensure an insulated connection. | + | Wrap Electric Tape around the crocodile clips and multimeter probes |
| {{: | {{: | ||
| Line 119: | Line 126: | ||
| Connect the Variac to a plug socket and connect another plug to the Transformer output. | Connect the Variac to a plug socket and connect another plug to the Transformer output. | ||
| - | {{: | + | {{: |
| ** DO NOT CONNECT THE PLUG TO THE AC TEST BOX ** | ** DO NOT CONNECT THE PLUG TO THE AC TEST BOX ** | ||
| Line 146: | Line 153: | ||
| Now go to the AC Monitor Tab, you should see: | Now go to the AC Monitor Tab, you should see: | ||
| - | {{: | + | {{: |
| - | === Step 12 === | + | === Step 13 === |
| On the AC Monitor Tab: | On the AC Monitor Tab: | ||
| Line 155: | Line 162: | ||
| Change Circuit Type to 'Three Phase' | Change Circuit Type to 'Three Phase' | ||
| - | {{: | + | {{: |
| Click ' | Click ' | ||
| Line 161: | Line 168: | ||
| All Phases should stop being unavailable and say ' | All Phases should stop being unavailable and say ' | ||
| - | {{: | + | {{: |
| - | === Step 12 === | + | === Step 14 === |
| - | **MAKE SURE ALL CONNECTIONS ARE ACCURATE BEFORE TURNING POWER ON** | + | **MAKE SURE ALL CONNECTIONS ARE ACCURATE BEFORE TURNING POWER ON (Step 2 - Step 5 otherwise you could potentially damage the PCB)** |
| Turn on the Variac Power, the Blue LCD display on it should state the voltage. | Turn on the Variac Power, the Blue LCD display on it should state the voltage. | ||
| Line 170: | Line 177: | ||
| Turn the Dial to output 25V. | Turn the Dial to output 25V. | ||
| - | {{: | + | {{: |
| - | The Phase A, B and C Line-Neutral Voltages should be approximately 31V | + | The Phase A, B ,C Line-Neutral Voltages should be approximately 31V |
| - | Phase A, B, C Current should be approximately 1.2A | + | The Phase A, B, C Current should be approximately 1.4A |
| - | === Step 13 === | + | The Phase A, B, C Real Power should be approximately 44W |
| + | |||
| + | === Step 15 === | ||
| Turn the Variac Dial to 125V | Turn the Variac Dial to 125V | ||
| - | {{: | + | {{: |
| **Keep away from the PCB, AC Test Box and PCB when power on.** | **Keep away from the PCB, AC Test Box and PCB when power on.** | ||
| - | The Phase A, B, C Line-Neutral Voltages should be approximately | + | The Phase A, B, C Line-Neutral Voltages should be approximately |
| - | The Phase A, B, C Current should be approximately 5.3A | + | The Phase A, B, C Current should be approximately 5.9A |
| - | === Step 14 === | + | The Phase A, B, C Real Power should be approxmiately 767W |
| + | |||
| + | === Step 16 === | ||
| Turn the Variac Dial to 250V | Turn the Variac Dial to 250V | ||
| - | {{: | + | {{: |
| **Keep away from the PCB, AC Test Box and PCB when power on.** | **Keep away from the PCB, AC Test Box and PCB when power on.** | ||
| Line 196: | Line 207: | ||
| The Phase A, B, C Line-Neutral Voltages should be approximately 251V | The Phase A, B, C Line-Neutral Voltages should be approximately 251V | ||
| - | The Phase A, B, C Current should be approximately | + | The Phase A, B, C Current should be approximately |
| + | |||
| + | The Phase A, B, C Real Power should be approximately 2880 | ||
| + | === Step 17 === | ||
| + | Change the Set Parameter to: Device Instance | ||
| + | |||
| + | Change Set Dev Inst to: 1 | ||
| + | |||
| + | Click ' | ||
| + | |||
| + | === Packaging === | ||
| + | |||
| + | this will need pics and info The 3420 is always sent with a 3423, this is now being packaged together in the same box. | ||
| + | this SOP will need updating once the 3420 has had its PCB re-designed. | ||
| + | |||
| + | |||
| + | --- // | ||
internal/proddocs/3420.1638789439.txt.gz · Last modified: 2023/07/12 14:11 (external edit)