internal:proddocs:3420 [2021/12/06 11:17] kacperinternal:proddocs:3420 [2023/07/26 10:01] (current) eral
Line 70: Line 70:
  
 ===== Testing Instructions ===== ===== Testing Instructions =====
 +
 +<adm warning>DUE TO ELECTRIC SHOCK HAZARD, TESTING WILL BE DONE BY ENGINEERING TEAM.</adm>
  
 <note warning> The 3420  Testing process involves HIGH VOLTAGE, Make sure to disconnect power when handling connections, and stay away from PCB, Variac and Test Box when power is turned on! </note>  <note warning> The 3420  Testing process involves HIGH VOLTAGE, Make sure to disconnect power when handling connections, and stay away from PCB, Variac and Test Box when power is turned on! </note> 
Line 83: Line 85:
   * Variac   * Variac
   * Electric Tape   * Electric Tape
 +  * Multimeter
  
 === Step 1 === === Step 1 ===
Line 105: Line 108:
  
 {{:internal:proddocs:ac_transformer_negative.jpg?800|}} {{:internal:proddocs:ac_transformer_negative.jpg?800|}}
 +
 +**Now Connect the black wire from the miltimeter to the same black current transformer output wire** 
  
 === Step 5 === === Step 5 ===
Line 110: Line 115:
  
 {{:internal:proddocs:ac_transformer_positive.jpg?800|}} {{:internal:proddocs:ac_transformer_positive.jpg?800|}}
 +
 +**Now Connect the Red wire from the miltimeter to the same red current transformer output wire** 
  
 ===Step 6 === ===Step 6 ===
-Wrap Electric Tape around the crocodile clips to ensure an insulated connection.+Wrap Electric Tape around the crocodile clips and multimeter probes to ensure an insulated connection.
  
 {{:internal:proddocs:electric_tape.jpg?800|}} {{:internal:proddocs:electric_tape.jpg?800|}}
Line 119: Line 126:
 Connect the Variac to a plug socket and connect another plug to the Transformer output. Connect the Variac to a plug socket and connect another plug to the Transformer output.
  
-{{:internal:proddocs:variac.jpg?800|}}+{{:internal:proddocs:variac.jpg?300|}}
  
 ** DO NOT CONNECT THE PLUG TO THE AC TEST BOX ** ** DO NOT CONNECT THE PLUG TO THE AC TEST BOX **
Line 146: Line 153:
 Now go to the AC Monitor Tab, you should see: Now go to the AC Monitor Tab, you should see:
  
-{{:internal:proddocs:ac_monitor_tab_monex.png?800|}}+{{:internal:proddocs:ac_monitor_tab_monex.png?500|}}
  
-=== Step 12 ===+=== Step 13 ===
 On the AC Monitor Tab: On the AC Monitor Tab:
  
Line 155: Line 162:
 Change Circuit Type to 'Three Phase' Change Circuit Type to 'Three Phase'
  
-{{:internal:proddocs:change_phase.png?800|}}+{{:internal:proddocs:change_phase.png?300|}}
  
 Click 'Send' Click 'Send'
Line 161: Line 168:
 All Phases should stop being unavailable and say '0', the frequency should say 49.9. All Phases should stop being unavailable and say '0', the frequency should say 49.9.
  
-{{:internal:proddocs:three_phase_ac_monitor.png?800|}}+{{:internal:proddocs:three_phase_ac_monitor.png?300|}}
  
-=== Step 12 === +=== Step 14 === 
-**MAKE SURE ALL CONNECTIONS ARE ACCURATE BEFORE TURNING POWER ON**+**MAKE SURE ALL CONNECTIONS ARE ACCURATE BEFORE TURNING POWER ON (Step 2 - Step 5 otherwise you could potentially damage the PCB)**
  
 Turn on the Variac Power, the Blue LCD display on it should state the voltage.  Turn on the Variac Power, the Blue LCD display on it should state the voltage. 
Line 170: Line 177:
 Turn the Dial to output 25V. Turn the Dial to output 25V.
  
-{{:internal:proddocs:25v_variac.jpg?800|}}+{{:internal:proddocs:25v_variac.jpg?300|}}
  
-The Phase A, B and C Line-Neutral Voltages should be approximately 31V+The Phase A, B ,C Line-Neutral Voltages should be approximately 31V
  
-Phase A, B, C Current should be approximately 1.2A+The Phase A, B, C Current should be approximately 1.4A
  
-=== Step 13 ===+The Phase A, B, C Real Power should be approximately 44W 
 + 
 +=== Step 15 ===
 Turn the Variac Dial to 125V Turn the Variac Dial to 125V
  
-{{:internal:proddocs:125v_variac.jpg?800|}}+{{:internal:proddocs:125v_variac.jpg?300|}}
  
 **Keep away from the PCB, AC Test Box and PCB when power on.** **Keep away from the PCB, AC Test Box and PCB when power on.**
  
-The Phase A, B, C Line-Neutral Voltages should be approximately 129V+The Phase A, B, C Line-Neutral Voltages should be approximately 130V
  
-The Phase A, B, C Current should be approximately 5.3A+The Phase A, B, C Current should be approximately 5.9A
  
-=== Step 14 ===+The Phase A, B, C Real Power should be approxmiately 767W 
 + 
 +=== Step 16 ===
 Turn the Variac Dial to 250V Turn the Variac Dial to 250V
  
-{{:internal:proddocs:250v_variac.jpg?800|}}+{{:internal:proddocs:250v_variac.jpg?300|}}
  
 **Keep away from the PCB, AC Test Box and PCB when power on.** **Keep away from the PCB, AC Test Box and PCB when power on.**
Line 196: Line 207:
 The Phase A, B, C Line-Neutral Voltages should be approximately 251V The Phase A, B, C Line-Neutral Voltages should be approximately 251V
  
-The Phase A, B, C Current should be approximately 10.4A+The Phase A, B, C Current should be approximately 11.4A 
 + 
 +The Phase A, B, C Real Power should be approximately 2880 
 +=== Step 17 === 
 +Change the Set Parameter to: Device Instance 
 + 
 +Change Set Dev Inst to: 1 
 + 
 +Click 'Send' 
 + 
 +=== Packaging === 
 + 
 +this will need pics and info The 3420 is always sent with a 3423, this is now being packaged together in the same box. 
 +this SOP will need updating once the 3420 has had its PCB re-designed. 
 + 
 + 
 + --- //[[chrissy@osukl.com|Christine Walsh]] 17/01/2022 08:57// updated
internal/proddocs/3420.1638789439.txt.gz · Last modified: 2023/07/12 14:11 (external edit)

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki