internal:proddocs:3501
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| internal:proddocs:3501 [2021/09/22 08:45] – chrissy | internal:proddocs:3501 [2023/12/04 13:19] (current) – kacper | ||
|---|---|---|---|
| Line 2: | Line 2: | ||
| <note warning> | <note warning> | ||
| - | Solder wires to PCB and insert cable tie into position see pic below | + | {{: |
| - | + | ||
| - | {{: | + | |
| ====== Programming ====== | ====== Programming ====== | ||
| - | Select device | + | Connect the unit to 24V NMEA power as shown |
| + | |||
| + | {{: | ||
| + | |||
| + | Connect the STM32 Programmer to the unit as shown | ||
| + | |||
| + | {{: | ||
| + | |||
| + | Open STM32 Programmer and go into the programming | ||
| + | |||
| + | {{: | ||
| + | |||
| + | Select the 'File Path' to be S:/ | ||
| + | |||
| + | {{: | ||
| + | |||
| + | Click " | ||
| + | |||
| + | {{: | ||
| + | |||
| + | You can now remove the STM32 programmer from the PCB, the Blue LED should be solid blue. | ||
| + | |||
| + | |||
| + | |||
| + | Now Open Monex Software (found in S:/ | ||
| + | |||
| + | On the Device Info Tab click, 'Get Serial' | ||
| + | |||
| + | {{: | ||
| + | |||
| + | Go To the ' | ||
| + | |||
| + | {{: | ||
| + | |||
| + | Then select vessel for which the unit will be used from S:/ | ||
| + | |||
| + | For Testing Purposes PEARL62 is used: | ||
| + | |||
| + | {{: | ||
| + | |||
| + | The Programming will begin, wait until " | ||
| + | |||
| + | {{: | ||
| + | |||
| + | ====== Testing ====== | ||
| + | |||
| + | Using Monex seet up the level transmit controls as shown below: | ||
| + | |||
| + | {{: | ||
| + | |||
| + | The received Level value should be 57.08% (red bar on the right of Monex) | ||
| - | {{: | + | The top left and top middle LED's should be flashing green every 2.5 seconds, and the blue LED should also be flashing every 2.5 seconds. |
| + | Change the level values to the ones shown below: | ||
| + | {{: | ||
| + | The received Level value should be 51.29% (red bar on the right of Monex) | ||
| + | Go to the Device Info tab and change the Hex switch value on the PCB, monitor Device Inst Upper/Lower to make sure it matches the switch value. | ||
| + | ====== Packaging ====== | ||
| + | Use a RPT112 box and a 200374 insert | ||
| + | {{: | ||
| + | --- // | ||
internal/proddocs/3501.1632300347.txt.gz · Last modified: 2023/07/12 14:11 (external edit)