Line 36: Line 36:
 {{:internal:proddocs:3501_monex_prodinfo.png?600|}} {{:internal:proddocs:3501_monex_prodinfo.png?600|}}
  
 +Go To the 'Programming' Tab and click on 3501, and then on 'Reprogram!' on the pop-up that appears
  
 +{{:internal:proddocs:3501_repro_pop-up.png?600|}}
  
 +Then select vessel for which the unit will be used from S:/Code/Production/3501/....
  
-<note important> +For Testing Purposes PEARL62 is used:
-Ensure Bit rate is set to 500 Then click (init). Power up device whilst holding SW1 then hit connect you may have to do this twice if error code appears. Ensure BLJB is unticked and then hit run</note>+
  
-{{:internal:proddocs:3501-12.jpg?600|}}{{:internal:proddocs:3501-11.jpg?600|}}+{{:internal:proddocs:3501_pearl62.png?600|}}
  
-The device will program ensure all operation flows are green.+The Programming will begin, wait until "Re-booting to Application Code" is displayed before you begin testing
  
-{{:internal:proddocs:3501-13.jpg?600|}} +{{:internal:proddocs:3501_rebooting_to_app_code.png?600|}}
-<note important> +
-Switch off PSU without pressing SW1</note>+
  
 +====== Testing ======
  
-Select Monex 3.10 Select Prod info and set serial number.  +Using Monex seet up the level transmit controls as shown below:
-<note>If working correctly all led's from 3-8 should flash in sequence</note> +
-  * Go to level transmit controls and change Instance to A B and C +
-{{:internal:proddocs:3501.1.jpg?600|}} +
-  * Click transmit to standby and change fuel levels to check function +
-{{:internal:proddocs:3501.2.jpg?600|}}+
  
- LED 3, 4 and 5 should blink green +{{:internal:proddocs:3501_test_1.png?600|}}
- Click water and fuel LED 3, 4 and 5 should blink red. +
-Change instance to D, E and F +
  
-{{:internal:proddocs:3501..4.jpg?600|}}+The received Level value should be 57.08% (red bar on the right of Monex)
  
-LED 3, 4 and 5 should be solid red and 6and 8 inactive. +The top left and top middle LED'should be flashing green every 2.5 seconds, and the blue LED should also be flashing every 2.5 seconds.
-Click water and fuel again LED 6, 7 and 8 should blink green.+
  
 +Change the level values to the ones shown below:
  
-Apply glue to LED's on board+{{:internal:proddocs:3501_test_2.png?600|}}
  
-{{:internal:proddocs:3501-8_2_.jpg?600|}}+The received Level value should be 51.29% (red bar on the right of Monex)
  
-Insert PCB into casing ensure it sits under the four taps, Tighten cable tie in position and insert yellow button. +Go to the Device Info tab and change the Hex switch value on the PCB, monitor Device Inst Upper/Lower to make sure it matches the switch value.
-insert side panels into place (cut to size on cable side) +
- +
-{{:internal:proddocs:3501-15.jpg?600|}}{{:internal:proddocs:3501-16.jpg?600|}} +
- +
-click the rest of the casing partially into place then insert front panel. +
-Then insert sping into orange slider switch and click everything into place, +
- +
-{{:internal:proddocs:3501-17.jpg?600|}} +
- +
-Test switch control on monex and check all information. +
-Label unit with required labels and print Data sheet (no manual for this unit) +
- +
-{{:internal:proddocs:3501-20.jpg?600|}}+
  