5250 Build Instructions

The 5250 PCB assembly contains components that are sensitive to electrostatic discharge (ESD) – please make sure you are wearing your wrist strap when handling.

Atmel Programming

The PCB requires both bootloader via Atmel Studio and main program via Atmel FLIP. Before continuing connect the PCB to the NMEA cable at your bench and power on the device to 12V.

Bootloader

Connect the Atmel ICE tool to the PCB.

  1. Open Atmel Studio
  2. Go to Device Programming
  3. Set fuses as per below picture
  4. Flash the AVRBootloader.hex file from S:/Code/Production/5250 Deck Gauge/AVRBootloader.hex
  5. Display should now read '88'.

Main Program

  1. Power off the PSU
  2. Hold a magnet over the right lip of the 7 segment display
  3. Power on the PSU. Display should read '8'. If it does not, repeat steps 1-3.
  4. Open Atmel Flip
  5. Ensure ATMega64C1 is the selected device
  6. Select Setting>Communication>CAN>PEAK>250kbit/s Then press Init and Connect (repeat this step up to 5 time until device is connected)
  7. Load the latest 5250 named hex file from S:/Code/Production/5250 Deck Gauge/
  8. Press Run

Warning

Before start potting, just after programming connect boards to Monex and check for the levels 88% and 100% to be sure all display segments are working properly!!!

Hardware Assembly

Bezel casting 202272 and gasket 202510.

Clean the front face of the bezel with a soft clean cloth, then cover with blue tape.

Remove backing from gasket to expose self adhesive side, with care, place self adhesive side of gasket into bezel, making sure correct orientation of gasket. .</note>

Rest printed glass (202271) onto the gasket, making sure correct orientation of glass and bezel casting. One hole at top and two holes at bottom.

Degrease polyacetal body with IPA and allow to dry before fitting. Place black polyacetal body into bezel casting. Make sure that the body is correctly aligned.

Warning

BE SURE BLACK BODY IS COMPLETELY FITTED TO THE BEZEL WITH NO ANY GAPS. APPLY HAND PRESS DEVICE FROM DIFFERENT EDGES TO ENSURE BLACK BODY INTO PLACE.

Use hand press to snap black body into place, make sure to protect the body from damage. See next image.

Protect black plastic body.

Remove rubber grommet from connector.

Please ensure potting room is at the temperature 20-25 degrees Celsius. Heater and dehumidifier must be left on at all times (Check Thermometer before starting procedure.)

Warning

BEFORE START MIXING THE CLEAR POTTING, CLEAR THE PRINTED GLASSES WITH IPA AND COTTON BUD AND LEAVE THEM TO DRY.

Pour clear gel (WACKER SILGEL) first - with mixing ratio 1.5/1 (Compaund A/B), weigh into cup and then follow document Epoxy degassing instructions QMF18 on how to degas the epoxy. Check all air bubbles have dispersed.

Mixing Table Compaund A - Compaund B

  • 1.5gr - 1gr
  • 10gr - 6.6gr
  • 15gr - 10gr
  • 20gr - 13.33gr
  • 25gr - 16.66gr
  • 30gr - 20gr
  • 35gr - 23.33gr
  • 40gr - 26.66gr

Note

MIX CLEAR POTTING FOR 60 SECONDS

Following Clear epoxy procedures 201266

  • PUT THE MIXED EPOXY INSIDE THE VACUUM CHAMBER.
  • FIRST VALVE MUST BE CLOSE AND SECOND VALVE MUST BE OPEN.
  • TURN ON THE COMPRESSOR AND WAIT UNTIL PRESSURE GAUGE BEING STABLE AND COUNT UP TO 40 SEC.
  • TURN OFF THE COMPRESSOR AND CLOSE THE SECOND VALVE (CLOSEST TO THE COMPRESSOR)
  • OPEN THE FIRST VALVE JUST A LITTLE BIT AND LET THE AIR FLOW INSIDE THE CHAMBER SLOWLY.
  • NOW POTTING MATERIAL MUST BE BUBBLE-FREE.

Warning

ADD JUST ENUGH TO COVER THE PRINTED GLASS A THIN LAYER. NEVER OVERFILL CLEAR POTTING.

Brush face of display with degassed epoxy, and then gently place PCB into the clear epoxy taking care to align PCB in the correct orientation. Ensure PCB display lines up with printed window.

Once aligned correctly, place the units inside de-gassing chamber max. 5 at same time and fallow the previous steps above. After second de-gassing work check for display alignment one more time and move it if necessary and allow 24 hours before second potting procedure.

Inspection check before next stage – is the display lined up parallel to rectangular window, is PT1 lined up with round window? If the display has moved position Do not try to move it, remove clear potting and start again.

When clear epoxy is dry and PCB is securely in place, fill back of Deck Gauge with black epoxy compound 201265. Fill just below the lip of rotary switch taking care not to let potting compound go down into connectors or switch. Leave to cure for 24 hrs.

This board is now potted in black resin 201265 up to the level of the rotary switch.

connect assembly to Monex set serial numbers and double check the function of the display.

Warning

Before packing print Manual and label unit.

Return the hex nut to connector, AND COVER WITH BLUE FILM.

internal/proddocs/5250.1747391556.txt.gz · Last modified: 2025/05/16 10:32 by david