internal:proddocs:5720
This is an old revision of the document!
Warning: Undefined array key 1 in /data/docs.osukl.com/public_html/lib/plugins/note/syntax.php on line 103
Table of Contents
5720 BUILD INSTRUCTIONS
The 5720 PCB assembly contains components that are sensitive to electrostatic discharge (ESD) – please make sure you are wearing your wrist strap when handling.
<note important> Once the PCB has been assembled, the unit must be programmed and tested before final assembly and potting.
Assembly Instructions
Programming and Test
- 1. Power Supply
- 2. Voltmeter
- 3. NMEA 2000 Network
- 4. PC running MONEX 3.6 or later
- 5. 5720 Test Harness
- 6. STM32 STLink Programmer with Tag Connect Lead.
Connect the NMEA 2000 power calbe and turn the power supply to 12V before turning it on.
INSERT IMAGE
Connect the STM32 Programmer to CONN2 on the 5720 PCB as shown below
INSERT IMAGE
Open STM32 Programmer, click 'Connect' and go to the Programming tab
Select File path S:/Code/Production/5720/stm32bootloaderV200
Manual Printing Instructions
- Go to (S) Drive.
- Parts Documents.
- Select 5720
- Select PDF's.
- Select 5720 user manual and print.
Label Printing Instructions
- Choose labels required
- Select (LabelDirect)
- Close (Pop Up)
- Go to file-open
- Select - Parts documents
- Select - 5720
- Select - Labels
- Select - UL_5720
- Highlight Serial number and change in Text box.
- Go to Incrementing number Properties and change serial number.
- Go to file -Print Setup
- Select bradyBBP11-34L(copy 1) and select Calibrate.
- label will calibrate.
Packaging
needs updating
internal/proddocs/5720.1701776757.txt.gz · Last modified: 2023/12/05 11:45 by kacper