-====== 5906 6 Channel Load Controller ======  
-INSERT IMAGE OF UNIT 
-==== Features ==== 
-    * Inputs for DC Battery Supply (28V Max) 
-    * Heartbeat LED Confirming NMEA Transmission  
-    * NMEA2000® Micro-C Interface Plug 
-    * Robust Environmentally protected enclosure and connections 
-    * The unit reports Switch Status (Voltage and Channel Current) 
-    * Settable channel fuse current and fuse tripping time. 
- 
----- 
- 
----- 
- 
----- 
- 
- 
-====The Oceanic Sytems 5906 6 Channel Load Controller protects each channel with an accurate settable tripping current and tripping time, reporting the channel status over the NMEA2000® network==== 
- 
-The unit is able to provide power to 6 individual channels, each with a configurable fuse and tripping time. 
- 
-The unit is suitable for powering loads like Lighting, x ,x. Each channel contains a status LED for displaying if the channel is On/Off/Tripped. 
- 
-The Power connections utilise copper tube crimps with an M6 Bolt allowing for secure and reliable connection. 
- 
-The unit utilises a waterproof and corrosion resistant DT15-12PA Deutsch Connector for the 6 output channels, which allows for a secure and reliable connection. 
- 
-The 5906 has a blue LED that flashes as the unit transmits data over the network with configuration done with a suitable Oceanic Systems Display Unit, Our Puma PC software or pre-configuration when ordering direct from Oceanic Systems.  
- 
-Up to 254 units can be present on a single network. 
- 
-====Unit Dimensions==== 
- 
-INSERT DIMENSIONS 
- 
-====5099 Male Deutsch Adaptor Kit==== 
- 
-INSERT IMAGE 
- 
- 
-====Design Standards==== 
-|NMEA2000®|Level B| 
-|Maritime Nav and RadioComm Equipment|IEC60945| 
-|CE and FCC|Electromagnetic Compatibility| 
- 
-====NMEA2000® PGNs==== 
-^Type^PGN Number^PGN Name^ 
-|Monitor|PGN127501|Binary Status Report| 
-|Protocol|PGN059392|ISO Acknowledgement| 
-|:::|PGN059904|ISO Request| 
-|:::|PGN060928|ISO Address Claim| 
-|:::|PGN126208|Command/Request Group| 
-|:::|PGN126464|Tx/Rx PGN List| 
-|:::|PGN126993|Transmit Heartbeat| 
-|:::||PGN126996|Product Information| 
-|:::|PGN126998|Configuration Information| 
- 
-==== Electrical and Mechanical ==== 
- 
-^Parameter^Value^Comment^ 
-|Operating Voltage|9 to 32 Volts|DC Voltage| 
-|Power Consumption|80mA @ 24V|Average Operating| 
-|Load Equivalence Number|2|LEN| 
-|Reverse Battery Protection|????|Indefinitely| 
-|Load Dump Protection|????|SAE J1113| 
-|Size|mm|????| 
-|Weight|gr|????| 
- 
-==== Environmental ==== 
- 
-^Parameter^Values^ 
-|IEC 60954 Classification|Protected| 
-|Degree of Protection|IP64| 
-|Operating Temperature|????| 
-|Storage Temperature|-40°C to 70°C| 
-|Relative Humidity|93%RH @40° per IEC60945-8.2| 
-|Vibration|2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7| 
-|Electromagnetic Emission |Conducted and Radiated Emission per IEC 60945-9| 
-|Electromagnetic Immunity |Conducted, Radiated, Supply, and ESD per IEC 60945-9| 
-|Safety Precautions|Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945- 12| 
- 
- 
  
internal/proddocs/5906.1667549931.txt.gz · Last modified: 2023/07/12 14:11 (external edit)