 ===== Assembling/Connecting and Testing Seatek Engine Adapter using Test Box ===== ===== Assembling/Connecting and Testing Seatek Engine Adapter using Test Box =====
 **This Section outlines all connections that need to be made before testing can begin and all testing that follows** **This Section outlines all connections that need to be made before testing can begin and all testing that follows**
 +
 +==== Before Starting ====
 +Before you begin testing you must cut a track on the PCB with a scalpel and carry out a continuity check using a multimeter to make sure the track is definitely cut.
 +The track you should cut is shown below:
 +
 +{{:internal:proddocs:cutting_track.jpg?800|}}
  
 ==== Step 1 ==== ==== Step 1 ====
Line 72: Line 78:
 You Will See: You Will See:
  
-{{:internal:proddocs:step_10.png?800|}}+{{:internal:proddocs:step_10_-_v2.png?800|}}
  
 Set The 'Instance' to 0. Set The 'Instance' to 0.
Line 88: Line 94:
 Now Test if the 'Start' functionality works correctly. Now Test if the 'Start' functionality works correctly.
  
-Turn the Ignition switch all the way to the right until you see the red LED light on the Seatek Test Box.+Turn the Ignition switch all the way to the right until you see the Green LED Turn Yellow on the Seatek Test Box.
  
-{{:internal:proddocs:start_-_90_deg.jpg?800|}} +The 'Start' box on monex should light Yellow.
- +
-The 'Start' box on monex should light yellow, and the 'Stop' box on Monex should stop being red.+
  
 {{:internal:proddocs:step_12.png?800|}} {{:internal:proddocs:step_12.png?800|}}
Line 119: Line 123:
  
 ==== Step 15 ==== ==== Step 15 ====
-The RPM reading should be 2550 (+-30)+The RPM reading should be 2550 (+-50)
  
 {{:internal:proddocs:step_15.png?800|}} {{:internal:proddocs:step_15.png?800|}}
Line 259: Line 263:
  
 ==== Step 22 ==== ==== Step 22 ====
-Now Turn Switch 8 (SW8) using a flat head screwdriver and observe the OIL Temperature Tab On Monex.+Now Turn Switch 8 (SW8) using a flat head screwdriver and observe the WATER Temperature Tab On Monex.
  
 You Should Get the following Results: You Should Get the following Results:
Line 283: Line 287:
 {{:internal:proddocs:left_green_led.jpg?800|}} {{:internal:proddocs:left_green_led.jpg?800|}}
  
-{{:internal:proddocs:sw8_-_left_green_light.png?800|}}+{{:internal:proddocs:step_22.png?800|}}
  
 Keep Switch 8 in Position 1 when finished Step 22 to keep LED off. Keep Switch 8 in Position 1 when finished Step 22 to keep LED off.
Line 296: Line 300:
 {{:internal:proddocs:both_green_led.jpg?800|}} {{:internal:proddocs:both_green_led.jpg?800|}}
  
-{{:internal:proddocs:monex_-_led_test.jpg?800|}}+{{:internal:proddocs:step_23.png?800|}}
  
 **Turn the LEDs off again when step 23 is completed** **Turn the LEDs off again when step 23 is completed**
Line 311: Line 315:
 Now click the "START" Button on Monex ** - Nothing Should happen** Now click the "START" Button on Monex ** - Nothing Should happen**
  
-Now click the "Ignition" Button on Monex, it should light Red+Now click the "Ignition" Button on Monex, it should light Red and the start button should now light Yellow (you should hear relay click on the Seatek Engine Adapter).
- +
-Now if you click the "Start" Button again, it should turn yellow and you should hear the relay click in the Seatek Engine Adapter:+
  
 {{:internal:proddocs:monex_-_push_button_start.png?800|}} {{:internal:proddocs:monex_-_push_button_start.png?800|}}
  
-Click the 'Stop' Button, you should hear the relay click again and the Red Stop Button should light Red.+Click the 'Stop' Button, you should hear the relay click again and the Start button should turn off (you will again hear a relay click on the Seatek Engine Adapter). 
 + 
 +Click the Ignition Button again to turn it off, The Stop button should light Red. 
 + 
 +==== Step 25 ==== 
 + 
 +Now Test the STOP functionality of the Seatek Test Box. 
 + 
 +Do This by turning the ignition switch at 45 deg to the right in the 'on' position. 
 + 
 +INSERT IMAGE OF SEATEK TEST BOX 
 + 
 +Monex Should look like this: 
 + 
 +INSERT IMAGE OF MONEX 
 + 
 +Now Proceed to press and HOLD the STOP button on the Seatek test box and monitor Monex 
 + 
 +**IF THE STOP RELAY ON SEATEK PCB TOGGLES RAPIDLY THEN STOP TESTING** 
 + 
 +Monitor Monex while holding the button, it should look as follows: 
 + 
 +INSERT IMAGE OF MONEX 
 + 
 +If there is no rapid toggling then hold down the stop button on the test box and proceed to turn the ignition switch all the way to the right - On monex the STOP button should not be lit, while the START button should light Yellow. 
 + 
 +IF THIS IS NOT THE CASE THEN STOP TESTING AND ASK DEV
  
-Click the Ignition Button again to turn it off.+Now hold down the STOP button again, and click START on monex - START should not light, and STOP should be constantly lit RED.
  
-**Return all switched to position 1 and return the ignition switch to the starting vertical position**+**Return all switched to position 1 and return the ignition switch to the starting vertical position*
  
 **Turn Power off** **Turn Power off**
  
 **IF ALL TESTS WERE ACCURATE THEN TESTING IS COMPLETED, IF YOU HAVE ANY DOUBTS THEN ASK DEV** **IF ALL TESTS WERE ACCURATE THEN TESTING IS COMPLETED, IF YOU HAVE ANY DOUBTS THEN ASK DEV**