| + | ====== Programming Instructions ====== | ||
| + | |||
| + | **J1939 to NMEA 2000 Flashing Guide.** | ||
| + | ** | ||
| + | MPLAB ICD 3 Connection** | ||
| + | |||
| + | **Connect the J1939 to NMEA2000 adapter RJ-11 jack to the MPLAB ICD 3 RJ11 connector ** | ||
| + | |||
| + | {{: | ||
| + | |||
| + | **CAN Network power connection** | ||
| + | |||
| + | **Connect the J1939 to NMEA2000 adapter to the CAN network power source using the CAN connector** | ||
| + | |||
| + | {{: | ||
| + | |||
| + | **Open MPLAB IPE** | ||
| + | |||
| + | {{: | ||
| + | |||
| + | **Now configure MPLAB IPE to the correct settings for interfacing with the J1939 to NMEA2000 adaptor** | ||
| + | |||
| + | {{: | ||
| + | |||
| + | **Ensure the values are correct then press connect** | ||
| + | |||
| + | {{: | ||
| + | |||
| + | **Then select the Hex file you wish to load by clicking the browse button** | ||
| + | |||
| + | **This dialogue should then appear to enable you to select a Hex file for programming** | ||
| + | |||
| + | {{: | ||
| + | |||
| + | ** | ||
| + | The location of the Hex files for this particular product is located in S: | ||
| + | |||
| + | ** | ||
| + | **Double check that you have selected the correct Hex file and it has been loaded successfully** | ||
| + | |||
| + | {{: | ||
| + | |||
| + | ** | ||
| + | Once you are satisfied the correct Hex file has been selected and loaded successfully you can then proceed to program the J1939 to NMEA2000 adaptor. | ||
| + | |||
| + | Press the Program button | ||
| + | ** | ||
| + | |||
| + | **Keep an eye on the console output window for feedback on how the programming procedure is running. | ||
| + | |||
| + | |||
| + | At the end of the programming procedure you will be greeted with a Programming/ | ||
| + | ** | ||
| + | |||
| + | **You can again verify what has been programmed by pressing the verify button** | ||
| + | |||
| + | **Once MPLAB IPE has verified the programmed hex you will be greeted with a message in the output console | ||
| + | |||
| + | ** | ||
| + | |||
| + | **At this point programming and verification on this device (J1939 to NMEA2000 adaptor) is now complete you may now disconnect the CAN power connector and the MPLAB ICD 3 RJ-11 connector. | ||
| + | |||
| + | |||
| + | {{: | ||
| + | |||
| + | |||
| + | |||
| + | ====== Testing Procedure====== | ||
| + | |||
| + | |||
| + | Select the test equipment from the shelf | ||
| + | |||
| + | |||
| + | |||
| + | |||
| + | |||
| + | {{: | ||
| + | |||
| + | |||
| + | Get this test equipment from the shelf | ||
| + | Using test lead, fit 3x wires | ||
| + | White / black / blue | ||
| + | |||
| + | Connect the J1939 simulator | ||
| + | Note –you will require 3 cables from the network to do the test, | ||
| + | |||
| + | Once this is connected, the green LED will also flash rapidly. | ||
| + | |||
| + | {{: | ||
| + | |||
| + | Image with all 3 cables connected below. | ||
| + | |||
| + | {{: | ||
| + | |||
| + | See pic below for program. | ||
| + | |||
| + | {{: | ||
| + | |||
| + | Check all instances again | ||
| + | |||
| + | Check the up / down buttons, as long as the values change the unit is ok. | ||
| + | |||
| + | This completed programming and test. | ||
| + | |||
| + | Add 4x 200943 spacers to existing studs in metalwork. | ||
| + | |||
| + | Place the board 10262 in to the housing. Remove the rubber grommet and nut from PL1. | ||
| + | |||
| + | |||
| + | {{: | ||
| + | |||
| + | Screw 201485 onto studs using the 5mm long socket securing the board to the housing. | ||
| + | Taking time to align the two switches with the top cover. | ||
| + | |||
| + | |||
| + | {{: | ||
| + | |||
| + | |||
| + | Place the rear cover 201030 on to the unit and screw down using screw 201074 making sure the countersunk holes are facing outwards towards you. | ||
| + | |||
| + | {{: | ||
| + | |||
| + | Once the backing plate is secured, place the Oceanic Systems product description and serial number sticker onto the unit side panel square and central as shown. | ||
| + | |||
| + | {{: | ||
| + | |||
| + | This can now be packed into its box with sleeve and QC label. | ||
| + | |||
| + | |||
| + | |||
| + | |||