internal:proddocs:3185 [2022/09/12 07:53] – created chrissyinternal:proddocs:3185 [2023/07/12 14:33] (current) – external edit 127.0.0.1
Line 8: Line 8:
 T10 Torx security bit,     T10 Torx security bit,   
 17mm spanner.**  17mm spanner.**
 +
 +====== Programming Instructions ======
 +
 +**J1939 to NMEA 2000 Flashing Guide.**
 +**
 +MPLAB ICD 3 Connection**
 +
 +**Connect the J1939 to NMEA2000 adapter RJ-11 jack to the MPLAB ICD 3 RJ11 connector **
 +
 +{{:internal:proddocs:3185..1.png?600|}}{{:internal:proddocs:3185..2.png?600|}}
 +
 +**CAN Network power connection**
 +
 +**Connect the J1939 to NMEA2000 adapter to the CAN network power source using the CAN connector**
 +
 +{{:internal:proddocs:3185..3.png?600|}}{{:internal:proddocs:3185..4.png?600|}}
 +
 +**Open MPLAB IPE**
 +
 +{{:internal:proddocs:3185..5.png?600|}}
 +
 +**Now configure MPLAB IPE to the correct settings for interfacing with the J1939 to NMEA2000 adaptor**
 +
 +{{:internal:proddocs:3185..6.png?600|}}
 +
 +**Ensure the values are correct then press connect**
 +
 +{{:internal:proddocs:3185..7..png?600|}}
 +
 +**Then select the Hex file you wish to load by clicking the browse button**
 +
 +**This dialogue should then appear to enable you to select a Hex file for programming**
 +
 +{{:internal:proddocs:3185..8.png?600|}}
 +
 +**
 +The location of the Hex files for this particular product is located in S:\Code\Production\3185 J1939 to NMEA2000 Adaptor
 +
 +**
 +**Double check that you have selected the correct Hex file and it has been loaded successfully**
 +
 +{{:internal:proddocs:3185..9.png?600|}}
 +
 +**
 +Once you are satisfied the correct Hex file has been selected and loaded successfully you can then proceed to program the J1939 to NMEA2000 adaptor.
 +
 +Press the Program button
 +**
 +
 +**Keep an eye on the console output window for feedback on how the programming procedure is running.
 + 
 +
 +At the end of the programming procedure you will be greeted with a Programming/Verify complete message.
 +**
 +
 +**You can again verify what has been programmed by pressing the verify button**
 +
 +**Once MPLAB IPE has verified the programmed hex you will be greeted with a message in the output console
 + 
 +**
 +
 +**At this point programming and verification on this device (J1939 to NMEA2000 adaptor) is now complete you may now disconnect the CAN power connector and the MPLAB ICD 3 RJ-11 connector.
 +
 +
 +{{:internal:proddocs:3185.1.png?600|}}
 +
 +
 +
 +====== Testing Procedure======
 +
 +
 +Select the test equipment from the shelf
 +
 +
 +
 +
 +
 +{{:internal:proddocs:3185..10.png?600|}}
 +
 +
 +Get this test equipment from the shelf
 +Using test lead, fit 3x wires
 +White / black / blue
 +
 +Connect the J1939 simulator
 +Note –you will require 3 cables from the network to do the test,
 +
 +Once this is connected, the green LED will also flash rapidly.
 +
 +{{:internal:proddocs:3185..11.png?600|}}
 +
 +Image with all 3 cables connected below.
 +
 +{{:internal:proddocs:3185..12.png?600|}}
 +
 +See pic below for program.
 +
 +{{:internal:proddocs:3185..13.png?600|}}
 +
 +Check all instances again
 +
 +Check the up / down buttons, as long as the values change the unit is ok.
 +
 +This completed programming and test.
 +
 +Add 4x 200943 spacers to existing studs in metalwork.
 +
 +Place the board 10262 in to the housing. Remove the rubber grommet and nut from PL1.
 +
 +
 +{{:internal:proddocs:3185..14.png?600|}}
 +
 +Screw 201485 onto studs using the 5mm long socket securing the board to the housing.
 +Taking time to align the two switches with the top cover.
 +
 +
 +{{:internal:proddocs:3185..15.png?600|}}
 +
 +
 +Place the rear cover 201030 on to the unit and screw down using screw 201074 making sure the countersunk holes are facing outwards towards you.
 +
 +{{:internal:proddocs:3185..16.png?600|}}
 +
 +Once the backing plate is secured, place the Oceanic Systems product description and serial number sticker onto the unit side panel square and central as shown.
 +
 +{{:internal:proddocs:3185-16.png?600|}}
 +
 +This can now be packed into its box with sleeve and QC label.
 +
 +
 +
 +
  
  