User Tools

Site Tools


internal:proddocs:3350

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
internal:proddocs:3350 [2021/06/23 15:03] chrissyinternal:proddocs:3350 [2025/05/16 09:34] (current) – [Packaging] david
Line 5: Line 5:
 ====== Programming Instructions ====== ====== Programming Instructions ======
  
 +<note important><note warning> Any old revision boards need to be programmed using (FLIP)</note></note> 
 +  * Select device: AT89C51CC03
 +  * Select: 3350-Wv200.hex  (Water)
 +  * Select: 3350-Fv200.hex (Fuel)
 +  * Select: 3350-Gv200.hex (Grey water)
 +  * Select 3350-HTPO.200.hex (black)
 +  * Select: CAN, 
 +  * Select : PEAK
 +  * Select: INIT
 +  * Select: Connect
 {{:internal:proddocs:33501-1.png|}} {{:internal:proddocs:33501-1.png|}}
 +
 +<note important> All new revision boards use Atmel</note>
  
   -   Open Atmel Studio.   -   Open Atmel Studio.
   - ATMEL PROGRAMMING   - ATMEL PROGRAMMING
   - FUSES: All off except BOOTRST and SPIEN   - FUSES: All off except BOOTRST and SPIEN
-  - BOOTSIZE = 4096_7800+  - BOOTSIZE = 2048_7800
   - CKSEL = 16KCK/14CK +64ms (Last option)   - CKSEL = 16KCK/14CK +64ms (Last option)
   - Then program the fuses.   - Then program the fuses.
Line 22: Line 34:
   - Disconnect the PCB   - Disconnect the PCB
  
 +<note>HTPO on monex is Black when testing</note>
 ====== Assembly Procedure ====== ====== Assembly Procedure ======
  
Line 28: Line 41:
 <note important> note correct orientation. One side has 5 pins the other has 6. (The header pins may need to be trimmed down by approx 3 mm to allow better fitment of the outer casing.) <note important> note correct orientation. One side has 5 pins the other has 6. (The header pins may need to be trimmed down by approx 3 mm to allow better fitment of the outer casing.)
 </note> </note>
-The unit is now connected to the Monex system to check the LED Function @100% and 88% this ensures that all LED bars required to illuminate are lit, and check the Alarm Light function.+The unit is now connected to the Monex system to check the LED Function @100% and 88% this ensures that all LED bars required to illuminate are lit, and check the Alarm Light function. Check the lights dim when the sensor is covered. Check the alarm works at below 20% for Fuel and Fresh water, and at above 80% for Grey and Black water.
  
 {{:internal:proddocs:3350-2.png|}} {{:internal:proddocs:3350-2.png|}}
Line 83: Line 96:
  
 ===== Printing Manual Instructions ===== ===== Printing Manual Instructions =====
 +
   - Go to (S) Drive.   - Go to (S) Drive.
   - Parts Documents.   - Parts Documents.
Line 89: Line 103:
   - Select 3350_user manual and print.   - Select 3350_user manual and print.
  
 +<note warning>Ensure manual is checked for packaging contents</note>
 ===== Printing Labels ===== ===== Printing Labels =====
   * - Choose labels required    * - Choose labels required 
Line 106: Line 121:
   *   - Select bradyBBP11-34L(copy 1) and select Calibrate.   *   - Select bradyBBP11-34L(copy 1) and select Calibrate.
   *   - label will calibrate.   *   - label will calibrate.
 +
 +===== Inspection =====
 +  *   Check serial number label is correct. 
 +  *   Ensure all parts are present. 
 +  *   Check for visual damage. 
 +  *   Ensure the unit works on Monex and test the alarm.
  
 ===== Packaging ===== ===== Packaging =====
  
 +  * 1 x Manual
 +  * Use RPT103 box
 +  * Insert 203406
 +  * Sleeve 203371
  
  
 +{{:internal:proddocs:3350-10.jpg?200|}}
  
 +{{:internal:proddocs:3350-11.jpg?200|}}
  
 + --- //[[david@osukl.com|David Whittle]] 16/05/2025 10:34// updated
  
  
internal/proddocs/3350.1624460588.txt.gz · Last modified: 2023/07/12 14:11 (external edit)

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki