| Line 5: | Line 5: | ||
| ====== Programming Instructions ====== | ====== Programming Instructions ====== | ||
| + | <note important>< | ||
| + | * Select device: AT89C51CC03 | ||
| + | * Select: 3350-Wv200.hex | ||
| + | * Select: 3350-Fv200.hex (Fuel) | ||
| + | * Select: 3350-Gv200.hex (Grey water) | ||
| + | * Select 3350-HTPO.200.hex (black) | ||
| + | * Select: CAN, | ||
| + | * Select : PEAK | ||
| + | * Select: INIT | ||
| + | * Select: Connect | ||
| {{: | {{: | ||
| + | |||
| + | <note important> | ||
| - Open Atmel Studio. | - Open Atmel Studio. | ||
| - ATMEL PROGRAMMING | - ATMEL PROGRAMMING | ||
| - FUSES: All off except BOOTRST and SPIEN | - FUSES: All off except BOOTRST and SPIEN | ||
| - | - BOOTSIZE = 4096_7800 | + | - BOOTSIZE = 2048_7800 |
| - CKSEL = 16KCK/14CK +64ms (Last option) | - CKSEL = 16KCK/14CK +64ms (Last option) | ||
| - Then program the fuses. | - Then program the fuses. | ||
| Line 22: | Line 34: | ||
| - Disconnect the PCB | - Disconnect the PCB | ||
| + | < | ||
| ====== Assembly Procedure ====== | ====== Assembly Procedure ====== | ||
| Line 28: | Line 41: | ||
| <note important> | <note important> | ||
| </ | </ | ||
| - | The unit is now connected to the Monex system to check the LED Function @100% and 88% this ensures that all LED bars required to illuminate are lit, and check the Alarm Light function. | + | The unit is now connected to the Monex system to check the LED Function @100% and 88% this ensures that all LED bars required to illuminate are lit, and check the Alarm Light function. Check the lights dim when the sensor is covered. Check the alarm works at below 20% for Fuel and Fresh water, and at above 80% for Grey and Black water. |
| {{: | {{: | ||
| Line 108: | Line 121: | ||
| * - Select bradyBBP11-34L(copy 1) and select Calibrate. | * - Select bradyBBP11-34L(copy 1) and select Calibrate. | ||
| * - label will calibrate. | * - label will calibrate. | ||
| + | |||
| + | ===== Inspection ===== | ||
| + | * Check serial number label is correct. | ||
| + | * | ||
| + | * Check for visual damage. | ||
| + | * | ||
| ===== Packaging ===== | ===== Packaging ===== | ||
| Line 121: | Line 140: | ||
| {{: | {{: | ||
| + | --- // | ||
internal/proddocs/3350.1624461017.txt.gz · Last modified: 2023/07/12 14:11 (external edit)