User Tools

Site Tools


internal:proddocs:3890

This is an old revision of the document!


3890 Build Instructions

Tools:

  • Multi meter
  • Terminal Crimping Pliers
  • Ambersil Cleaning Fluid (if required)

Test Procedure

  • Test that the Unit is functioning correctly. Using the Multi meter.
  • Apply 24 volts to the Input Terminal and measure the voltage at the output terminal which should be 13.6 volts.
{{:internal:proddocs:3890-6.png?600|}}{{:internal:proddocs:3890-3.png?600|}}

If the Power Adaptor is working correctly, the manufacturers label can now be carefully removed and replaced by the Oceanic Systems label with Part Number and Serial Number positioned as shown. If necessary use the Ambersil to assist in the removal of any adhesive remaining after removing the label