internal:proddocs:4291
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| internal:proddocs:4291 [2021/07/02 13:17] – chrissy | internal:proddocs:4291 [2023/07/12 14:33] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | ====== 4291 Build Instructions. ====== | + | ====== 4291/4925 Build Instructions. ====== |
| - | <note warning> | + | <note warning> |
| Line 9: | Line 9: | ||
| Connect unit to programming device. | Connect unit to programming device. | ||
| - | {{: | + | {{: |
| + | |||
| + | * Select STM32CubeProgrammer | ||
| + | * Connect to Unit | ||
| + | |||
| + | {{: | ||
| - | * Select Atmel studio | ||
| * Select Device programming | * Select Device programming | ||
| - | * Select required Fuses see pictures below. | ||
| - | {{: | + | {{: |
| + | |||
| + | * Browse and select the S:/ | ||
| + | |||
| + | {{: | ||
| + | |||
| + | * Click Start Programming Making sure all the checked boxes are correct | ||
| + | |||
| + | {{: | ||
| + | |||
| + | You can now disconnect the unit, if programming unsucessful, | ||
| + | |||
| + | * Open Monex and click 'Get Serial' | ||
| + | |||
| + | {{: | ||
| + | |||
| + | * Go to the Programming tab and match the device instance to the Target Select | ||
| + | |||
| + | {{: | ||
| - | * Select Memories | + | * Click on 4291 and the Reprogram on the pop-up |
| - | * Select | + | * Select |
| - | {{: | + | {{: |
| - | * Load Hex file (4291-v2.0.6.hex) | + | * The Device should start programming and should ' |
| - | * Place magnet in position see picture below | + | |
| - | {{: | + | |
| - | * Select Bit rate (250) | + | * Go Back to Device Info Tab and check that Model ID now shows as 4-20mA Tank Level Adapter |
| - | * Verify Flash | + | |
| - | {{: | + | {{: |
| ====== Test Procedure ====== | ====== Test Procedure ====== | ||
| Line 39: | Line 57: | ||
| • At the start of testing DUT has to be in default configuration state.</ | • At the start of testing DUT has to be in default configuration state.</ | ||
| + | | ||
| + | ===== Calibrating Sender without Hydrostatic Sensor ===== | ||
| | | ||
| **TEST EQUIPMENT USED** | **TEST EQUIPMENT USED** | ||
| - | * • NMEA2000 Network with PCAN-View NMEA2000® USB Adaptor | + | * 4291 Sender |
| + | * Flat Head Screwdriver | ||
| + | * 4-20mA Test Unit | ||
| + | * NMEA Network | ||
| + | * Magnet | ||
| + | === Step 1 === | ||
| + | * Power up the unit and check connection on Monex | ||
| + | * Connect the Test Box as shown in the picture below | ||
| - | * • Test unit | + | {{: |
| - | * • Calibrated Multimeter | + | |
| - | * • MONEX installed on a PC | + | |
| - | {{: | + | {{: |
| - | {{: | + | === Step 2 === |
| + | |||
| + | * Begin by Empty Calibrating the Sender, do this by setting the Test box to 0 and Left Hex Switch to ' | ||
| + | |||
| + | {{: | ||
| + | |||
| + | === Step 3 === | ||
| + | |||
| + | * Follow by Full Calibrating the Sender, do this by setting the Test Box to 100 and the Left Hex Switch to ' | ||
| + | |||
| + | {{: | ||
| + | |||
| + | === Step 4 === | ||
| + | * Open Monex and check that the fuel level shown matches the values below | ||
| + | |||
| + | Test Box 100 = 100% fuel | ||
| + | |||
| + | Test Box 50 = approximately 65% fuel | ||
| + | |||
| + | Test Box 0 = 0% fuel | ||
| + | |||
| + | === Step 5 === | ||
| | | ||
| - | {{: | + | * Now Cycle Through values 0-7 on the left switch and check if they match the Fluid Type on Monex (Shown below the fluid level Bar Graph) |
| - | Fit PCB to box – this will go either way round | + | 0 = Fuel |
| - | {{: | + | 1 = Fresh |
| - | Secure with 4 x spacers | + | 2 = Grey |
| - | Take care when fitting the spacer by the NMEA connector, as it may foul when fitting | + | 3 = Live Well |
| - | {{: | + | 4 = Oil |
| - | Fit top plate and screw down | + | 5 = Black |
| - | {{: | + | 6 = Gasoline |
| - | <note warning> | + | 7 = Rsvd |
| - | </ | + | |
| - | The screws must also be flush after fitting. | + | === Step 6 === |
| + | |||
| + | * Now Cycle Through values 0-F on the right switch and check if the value matches | ||
| - | {{: | + | ===== Fit PCB to box – this will go either way round ===== |
| - | Fit top label | + | {{: |
| - | {{: | + | <note warning> |
| - | The Adaptor is now ready for Labels, Connect to monex for serial numbers | + | <note important> |
| + | The Adaptor is now ready for Labels, Connect to monex for serial numbers</ | ||
| + | |||
| + | Fit top label | ||
| + | |||
| + | {{: | ||
| ====== Manual Printing Instructions ====== | ====== Manual Printing Instructions ====== | ||
| Line 105: | Line 158: | ||
| - label will calibrate. | - label will calibrate. | ||
| + | ====== Packaging ====== | ||
| + | * Use RPT103 box | ||
| + | * 2 parts insert 203613 | ||
| + | * Outer sleeve | ||
| + | * Contents 1 x 4291 Tank Level Adaptor | ||
| + | * 1 x User Manual | ||
| - | + | {{: | |
| - | + | ||
| - | + | ||
| - | + | ||
| - | + | ||
| - | + | ||
| - | + | ||
| - | + | ||
| - | + | ||
| - | + | ||
| - | + | ||
internal/proddocs/4291.1625231848.txt.gz · Last modified: 2023/07/12 14:11 (external edit)